Advertisement

Blood Glucose
Monitoring System
Works with the C
download from the App Store
Uses only C
ontour
blood glucose test strips.
USER GUIDE
D
®
ontour
iabetes
n
®
ext
app available for
or on Google Play
®
10 45
4 12 22
93
.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Contour Next GEN 9658

  • Page 1 Blood Glucose Monitoring System Works with the C app available for ® ontour iabetes download from the App Store or on Google Play ® 10 45 4 12 22 Uses only C ® ontour blood glucose test strips. USER GUIDE...
  • Page 2: Customer Service Checklist

    Customer Service Checklist Model number When speaking with the Customer Service representative: 9658 7917 7383 1. Have your C ontour ® GEN blood glucose meter ontour blood glucose meter, (with two 3-volt CR2032 or DL2032 coin cell • • • test strips, and ontour ®...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION • All parts of the kit are considered biohazardous and can potentially transmit infectious diseases, even after you have WARNING performed cleaning and disinfection. • For complete instructions on cleaning and disinfecting your meter Alternative Site Testing (AST) is not intended for use with and lancing device, see Cleaning and Disinfection on page 48.
  • Page 4 • Keep batteries away from children. Many types of batteries are • Measuring Range: 20 mg/dL–600 mg/dL of glucose in blood poisonous. If swallowed, immediately contact your poison control • Altitude: This system has not been tested at altitudes higher than center.
  • Page 5: Your Meter Features

    • The C GEN blood glucose monitoring system ontour • Do not use expired materials. Using expired material can cause has a measuring range of 20 mg/dL to 600 mg/dL. inaccurate results. Always check the expiration dates on your test ™...
  • Page 6: Table Of Contents

    Expected Test Result Values ............23 LO or HI Results .................23 Control Solution Testing ..............26 FEATURES Ascensia, the Ascensia Diabetes Care logo, Contour, Microlet, the No Coding logo, Logbook..................29 Second-Chance, the Second-Chance sampling logo, Smartcolor, and Smartlight are View Averages ................30 trademarks and/or registered trademarks of Ascensia Diabetes Care Holdings AG.
  • Page 7: Getting Started

    GETTING STARTED Your C GEN meter Change Individual Target Ranges ...........40 ontour Set smartLIGHT target range indicator ........42 Set Bluetooth Wireless Functionality ........43 The C app for Your ontour iabetes GEN meter ............44 ontour Download the C app ........45 10 45 4 12 22 ontour iabetes...
  • Page 8 GETTING STARTED Your C GEN meter Screen ontour Symbol What the Symbol Means Before Meal marker. After Meal marker. Time Date 10 45 4 12 22 No marker selected. Test Result Meal Marker A Target Range or Target Range setting. in Target smartLIGHT target range indicator setting.
  • Page 9: Check The Meter Display

    GETTING STARTED Your C test strip ontour NOTE: Your meter comes with a pre-set time, date, and target range. You can change these features in Settings. See Settings on page 31. Target Ranges The meter compares your blood sugar results with a Target Range (for example, 70 mg/dL–130 mg/dL) to let you know if your test result is above, in, or below your Target Range.
  • Page 10: Meal Markers

    TESTING Meal Markers Symbol What the Symbol Means Comparison/Target Range During a blood sugar test, you can attach a Meal Marker to your blood After Meal: Use the If you mark your result sugar result when the Meal Marker feature in the meter is turned After Meal marker when as After Meal, the meter On.
  • Page 11: Symptoms Of High Or Low Blood Glucose

    TESTING Fingertip Testing Low blood glucose (Hypoglycemia): • shakiness • passing out Ensure that you have the materials you need before you begin testing: • sweating • seizure • C GEN meter. ontour • fast heartbeat • irritability • C test strips.
  • Page 12 TESTING Prepare the Lancing Device 3. Insert the lancet firmly into the The lancing device graphics are for illustration purposes only. lancing device until the lancet Your lancing device may look different. Refer to your lancing comes to a complete stop. device insert for detailed instructions on preparing the lancing device.
  • Page 13: Get The Blood Drop: Fingertip Testing

    TESTING Insert the Test Strip Get the Blood Drop: Fingertip Testing CAUTION: Do not use expired materials. Using expired material can WARNING: Potential Biohazard cause inaccurate results. Always check the expiration dates on your • Always wash your hands with antibacterial soap and water and test materials.
  • Page 14: Select A Meal Marker

    TESTING Second-Chance sampling—Apply More Blood 3. Test immediately after you have formed a small, round blood 1. If the meter beeps twice and the screen displays 00 60 drop, as shown. a blinking blood drop with a plus sign, the test 4.
  • Page 15 TESTING Example: Example: If you scroll up to Before Meal, the Before Meal marker blinks. 118 15 Do not press the OK button or remove the test strip yet. You can select the blinking marker or choose a different Meal Marker. Example: If you scroll down to After Meal, the After Meal marker blinks.
  • Page 16: Set A Reminder

    TESTING Set a Reminder smartLIGHT target range indicator 1. Make sure the Reminder feature is On in Settings. When your blood sugar test is complete, the meter displays your result with the units, time, date, meal marker (if selected), and target range See Set Reminder Feature on page 38.
  • Page 17: Test Results

    TESTING Expected Test Result Values To move to the Home screen, Blood sugar values will vary depending on food intake, medication press the OK button dosages, health, stress, or activity. Nondiabetic plasma glucose concentrations should be less than 100 mg/dL in the fasting state and less than 140 mg/dL in the post-prandial state (after a meal).
  • Page 18 TESTING Eject and Dispose of the Used Lancet Control Solution 1. Do not use your fingers to WARNING remove the lancet from the lancing device. Shake the control solution well before testing. The lancing device usually provided with your kit has an CAUTION: Use only C ontour automatic lancet ejection feature.
  • Page 19: Control Solution Testing

    TESTING CAUTION: Do not use expired materials. The meter turns on, displaying a test strip with a 10 45 4 12 22 Using expired material can cause inaccurate flashing blood drop. results. Always check the expiration dates on your test materials. Level 1 and Level 2 control solutions are available and sold separately if not included in the meter kit.
  • Page 20: Features

    FEATURES Logbook 8. Immediately touch the tip of the The Logbook contains blood sugar test results and Meal Markers test strip to the drop of control that you have made to those test results. The Logbook holds up to solution. 800 results.
  • Page 21: View Averages

    FEATURES Settings If you scroll past the oldest entry, the meter In Settings you can: displays the End screen. • Change the time format. • Change the time. • Change the date format. • Change the date. If you see a LO or HI test result, go to LO or HI Results on page 23 for •...
  • Page 22: Change The Time

    FEATURES 4. Press the button to navigate to the setting you want to change. 5. To change the time format, if needed, press the button, then press the OK button. 5. Press the OK button when the setting you want to change is blinking. 10 45 10 45 6.
  • Page 23: Change The Date

    FEATURES Change the Date 7. To change the month (blinking), press the 4 12 22 1. Press and hold the OK button until the meter turns on. button, then press the OK button. The Home screen has 2 options: Logbook and Settings 10 45 4 12 22...
  • Page 24: Set Meal Markers

    FEATURES Set Meal Markers 4. Press the button repeatedly until the Sound symbol is blinking on the Settings screen, then press the OK button. 1. Press and hold the OK button until the meter turns on. The Home screen has 2 options: Logbook and Settings 10 45 4 12 22...
  • Page 25: Set Reminder Feature

    FEATURES Set Reminder Feature Change Overall Target Range When Meal Markers are On, you can set a Reminder to test your blood WARNING sugar after you mark a reading as Before Meal. If Meal Markers are Off, see Set Meal Markers on page 37. Discuss your Target Range settings with your health care 1.
  • Page 26: Change Individual Target Ranges

    FEATURES NOTE: There is only one Low target number for both the Before Meal 7. To change the blinking High end of the Overall 70 -1 80 and After Meal Target Ranges. Target Range, press the button. Change Low for Both Target Ranges 8.
  • Page 27: Set Smartlight Target Range Indicator

    FEATURES Set smartLIGHT target range indicator 5. To turn the smartLIGHT feature On or Off, press the button to display the option you want. Your meter comes with the smartLIGHT feature turned On. 6. Press the OK button. When the smartLIGHT target range indicator is On, the test strip port displays a color that indicates if your reading is above, in, or below your Set Bluetooth Wireless Functionality personal Target Range.
  • Page 28: The C

    FEATURES The C app for Your When your C GEN meter is paired with the ontour iabetes ontour app: GEN meter ontour iabetes ontour • You can set or change a Meal Marker in the meter Logbook from Your C GEN meter is designed to work with the ontour the app.
  • Page 29: Meter Care

    HELP 2. Press and HOLD the button for about When you have successfully paired your 3 seconds, until you see the blinking meter with the C app, Bluetooth symbol (as shown in Step 3). ontour iabetes the meter’s blue light and the Bluetooth A blue light blinks when you are in symbol display.
  • Page 30: Cleaning And Disinfection

    HELP Cleaning and Disinfection Evaluate your device after performing cleaning and disinfection to ensure that the procedure does not cloud the face/display of the meter and does not corrode or erode the plastic housing or buttons. WARNING For more information Always wash your hands with antibacterial soap and water and dry them well before and after testing or handling the meter, lancing US Food and Drug Administration.
  • Page 31: Transfer Results To The C

    HELP Disinfecting Your Meter Cleaning and Disinfecting Your Lancing Device Supplies needed for disinfecting: Refer to the instructions provided with your lancing device for cleaning and disinfection. • Clorox Germicidal Wipes containing 0.55% sodium hypochlorite (bleach). Transfer Results to the C ontour iabetes •...
  • Page 32: Batteries

    HELP Replace the Batteries Ensure your meter’s USB port door is completely closed when 1. Before replacing your batteries, not in use. turn off your meter. USB Port 2. Turn the meter over and slide the battery cover in the direction of the arrow.
  • Page 33: Technical Information

    TECHNICAL INFORMATION Error Code What It Means What to Do WARNING Testing Errors Keep batteries away from children. Many types of batteries Repeat the test with a new are poisonous. If swallowed, immediately contact your poison Testing Error strip. If the error persists, control center.
  • Page 34: Technical Information: User Accuracy

    TECHNICAL INFORMATION Technical Information: User Accuracy Technical Information: Precision A measurement repeatability study was conducted with the The C GEN meter results may vary slightly from ontour GEN blood glucose monitoring system using your actual blood glucose value due to slight differences in testing ontour 5 venous whole blood specimens with glucose levels from technique and the natural variation in test technology.
  • Page 35 TECHNICAL INFORMATION Intermediate measurement precision (which includes variability across interference to radio communications. However, there is no guarantee multiple days) was evaluated using control solutions at 5 glucose that interference will not occur in a particular installation. If this levels. With each control solution, each of 3 lots of C test equipment does cause harmful interference to radio or television ontour...
  • Page 36: Specifications

    TECHNICAL INFORMATION Specifications Electromagnetic Compatibility (EMC): The C ontour meter complies with the electromagnetic requirements specified in Test Sample: Capillary whole blood only IEC 60601-1-2 Edition 4.0. Electromagnetic emissions are low and Test Result: Referenced to plasma/serum glucose unlikely to interfere with other nearby electronic equipment, nor are Sample Volume: 0.6 μL emissions from nearby electronic equipment likely to interfere with the Measuring Range: 20 mg/dL–600 mg/dL of glucose in blood...
  • Page 37 TECHNICAL INFORMATION Symbol Standard Symbol Standard Explanatory Text Explanatory Text Graphic/Title Reference Graphic/Title Reference Indicates the need for the user ISO 15223-1, ISO 15223-1, to consult the instructions for Clause 5.1.5 Indicates the manufacturer’s Clause 5.4.4 Caution: Read use for important cautionary batch code so that the medical IEC 61010-2- all warnings and...
  • Page 38 TECHNICAL INFORMATION References 5. American Diabetes Association. 2. Classification and diagnosis of 1. US Food and Drug Administration. Use of fingerstick devices on more than one person poses risk for transmitting bloodborne diabetes: Standards of medical care in diabetes—2020. Diabetes pathogens: initial communication.
  • Page 39: Warranty

    TECHNICAL INFORMATION Warranty Manufacturer’s Warranty: Ascensia Diabetes Care warrants to the 4. Ascensia Diabetes Care has no knowledge of the performance of original purchaser that this instrument will be free from defects in the C GEN blood glucose meter when used with any ontour materials and workmanship for 5 years from the date of original test strips other than C...
  • Page 40 Index Settings ..........20, 31, 32, 34, 35, 37, 38, 42, 43 After Meal Marker ..............4, 8, 17, 37 Bluetooth wireless functionality ............43 Averages .....................30 Date .....................34 Batteries ...................4, 52, 53 Meal Markers ................37 Low Batteries ..............4, 52, 53 Reminder Feature ..............20, 38 Replacement ................52, 53 smartLIGHT target range indicator ..........42 Before Meal Marker ..............4, 8, 17, 37...
  • Page 41 Ascensia, the Ascensia Diabetes Care logo, Contour, Microlet, the No Coding logo, Second-Chance, the Second-Chance sampling logo, Smartcolor, and Smartlight are trademarks and/or registered trademarks of Ascensia Diabetes Care Holdings AG.

This manual is also suitable for:

Next gen 7917Next gen 7383

Table of Contents