January 17, 2025

My meter says 56 44 52 and can not see previous readings. How doing fix it?? Thanks

User image 678a5550dee9c
Birendra
April 4, 2025

can the batteries be charged

1 comments:
Mr. Anderson
April 4, 2025

No, the Contour NEXT ONE batteries cannot be charged. They are not rechargeable and must be replaced after about 1000 tests.

This answer is automatically generated

Wendy
May 8, 2025

Will it notify if blood test not in normal range

Summary of Contents for Contour NEXT ONE

  • Page 1 Blood Glucose Monitoring System...
  • Page 2 INTENDED USE IMPORTANT SAFETY INFORMATION The C ONE blood glucose monitoring system is ® ONTOUR WARNING intended to be used for the measurement of blood glucose in both insulin and non-insulin treated patients with diabetes as an aid for Serious Illness patients and their HCPs in monitoring the effectiveness of the patient’s The system should not be used to test critically ill patients.
  • Page 3 • All blood glucose measuring systems are considered PRECAUTIONS biohazardous. Health care professionals or persons using this • Read your C ONE user guide, the lancing ONTOUR system on multiple patients should follow the infection control device package insert, if provided, and all instructional materials procedure approved by their facility.
  • Page 4: Your Meter Features

    • The C ONE blood glucose monitoring system has a • If your control solution test result is out of range, contact ONTOUR measuring range of 0.6 mmol/L to 33.3 mmol/L. Diabetes Care Customer Service. See the back cover for contact information.
  • Page 5: Table Of Contents

    Turn Meal Markers On ..............23 Test Results ................24 Expected Test Result Values ............24 LO or HI Results .................25 Ascensia, the Ascensia Diabetes Care logo, Contour, Alternative Site Testing (AST): Palm ...........25 Glucofacts, and Second-Chance are trademarks and/or Control Solution Testing .............33 registered trademarks of Ascensia Diabetes Care Holdings AG.
  • Page 6 GETTING STARTED Your C ONE Meter Symptoms of High or Low Blood Glucose.........58 ONTOUR Specifications ................60 Up Button Warranty ..................64 • Press to scroll up Index ..................66 • Press and hold to keep scrolling OK Button • Press and hold to turn the meter On or Off •...
  • Page 7: Getting Started

    GETTING STARTED GETTING STARTED Your C ONE Meter Screen ONTOUR Symbol What the Symbol Means Test Result in Target Time No marker selected. A Target Range or Target setting. Meal Target Light (smartLIGHT) setting. Marker Meter is ready to test. Add more blood to strip.
  • Page 8: Your Contour Next One Meter

    GETTING STARTED Your C Test Strip • Share reports. ONTOUR • Discreetly view information. • Review your Fasting, Before Meal, After Meal, and Overall results on a daily graph. • Change meter settings, as necessary. The C app does these things for you: ONTOUR IABETES •...
  • Page 9: Initial Setup From The Meter

    GETTING STARTED Initial Setup from the Meter Set the Time The hour is blinking. OK Button 1. To change the hour, press the button on the outer ring. Press and hold the OK button for 2 seconds until the meter turns on. Outer Ring The screen displays the Power On Self Test.
  • Page 10: Target Ranges And Meal Markers

    GETTING STARTED Set the Date The year is blinking. Above Your Target Range. 1. To change the year, press the button, then press the OK button. Below Your Target Range. You can attach a Meal Marker to your blood sugar result using the 2.
  • Page 11: Testing

    TESTING You can change the time format, time, date format, date, Sound setting, Meal Marker setting, and the Target Light (smartLIGHT) WARNING: Potential Biohazard setting by going to the Home screen and selecting Settings • All parts of the kit are considered biohazardous and can See page 37.
  • Page 12 TESTING 4. Twist off the round protective 1. Remove the endcap from the lancing device. lancet cap. Save the cap for disposing of the used lancet. 2. Loosen the round protective cap on a lancet by rotating the cap 5. Replace the endcap. ¼...
  • Page 13: Get The Blood Drop: Fingertip Testing

    TESTING Insert the Test Strip Get the Blood Drop: Fingertip Testing NOTE: For Alternative Site Testing instructions, see page 25. CAUTION: Do not use expired materials. Using expired material can cause inaccurate results. Always check the expiration dates on your test materials. 1.
  • Page 14: Select A Meal Marker

    TESTING Select a Meal Marker NOTE: During a blood sugar test, if Meal Markers are On, you can CAUTION: Do not press the select a Meal Marker when the meter displays your result. You tip of the test strip against the cannot select a Meal Marker in the Settings screen.
  • Page 15 TESTING Meal Marker choices if Meal Marker feature is On 3. When the Meal Marker you Symbol What the Symbol Means Related Target Range want is blinking, press the OK Button OK button. Fasting: Use the Fasting marker when testing blood If you do not make a Meal Marker selection within 30 seconds, the sugar levels after fasting Fasting Target Range...
  • Page 16: About Meal Markers

    TESTING If the Target Light (smartLIGHT) setting is On, the test strip port About Meal Markers displays a colour representing your result value compared to the During a blood sugar test, you can attach a Meal Marker to your Before Meal, After Meal, or Overall Target Range. blood sugar result when the Meal Marker feature in the meter is turned On.
  • Page 17: Test Results

    TESTING Test Results LO or HI Results • If the meter beeps twice and WARNING displays the LO screen, your • Always consult your health care professional before blood sugar reading is under changing your medication based on test results. 0.6 mmol/L.
  • Page 18 TESTING For Alternative Site Testing, use the clear endcap. Your Get a Blood Drop: Alternative Site Testing ONE meter can be used for fingertip or palm testing. ONTOUR 1. Wash your hands and the puncture See the lancing device insert for detailed instructions on Alternative site with soap and warm water.
  • Page 19 TESTING Apply More Blood for Alternative Site Testing 1. If the meter beeps twice and the screen displays a blinking blood 6. Lift the lancing device straight up drop, the test strip does not have and away from the skin without enough blood.
  • Page 20 TESTING Meal Marker choices if the Meal Marker feature is On Eject and Dispose of the Used Lancet Symbol What the Symbol Means Related Target Range 1. Do not use your fingers to remove the lancet from the lancing device. Fasting: Use the Fasting The lancing device usually marker when testing blood...
  • Page 21: Control Solution Testing

    TESTING Control Solution WARNING WARNING • Do not calibrate your continuous glucose monitoring device from the control result. • Shake the control solution well before testing. • Do not calculate a bolus based on a control result. CAUTION: Use only C control ONTOUR solution (Normal, Low, and High) with...
  • Page 22 TESTING 8. Immediately touch the tip of the test strip to the drop of control solution. 4. Insert the grey square end of the test strip into the test strip port 9. Hold the tip in the drop until the until the meter beeps.
  • Page 23: Features

    • Turn Bluetooth On or Off. The Logbook is blinking. You must accept or change each setting with the OK button before moving to the next one. 2. To select the blinking Logbook symbol, press the OK button. Access Settings 3.
  • Page 24 FEATURES Change the Time 4. Continue to press the OK button until you see the Date Format screen. The time format is blinking. 1. To change the time format, if needed, press the button, then press the OK button. Date Format The date format (m/d or d.m) is blinking.
  • Page 25 FEATURES Set the Sound Set Meal Markers If your meter is not ON: If your meter is not ON: 1. Press and hold the OK button until the meter turns on. 1. Press and hold the OK button until the meter turns on. The Home screen has 2 options: Logbook and Settings The Home screen has 2 options: Logbook...
  • Page 26 FEATURES View Target Ranges 7. To move to the next Target Range, press the OK button. WARNING Discuss your Target Range settings with your health care The meter displays the Overall Target Range. professional. When the Meal Marker feature is On, your meter displays a 8.
  • Page 27 FEATURES If your meter is not ON: Set Bluetooth 1. Press and hold the OK button until the meter turns on. Bluetooth is not available until you pair your meter with a mobile The Home screen has 2 options: Logbook and Settings device.
  • Page 28: Pairing Mode

    HELP Pairing Mode 1. Clean the exterior of the meter using a moist (not wet) lint-free tissue with a mild detergent or disinfect using a disinfectant To pair your meter with the C app, download the ONTOUR IABETES solution, such as 1 part bleach mixed with 9 parts water. app and follow the instructions to Pair a Meter.
  • Page 29: Transfer Results To A Personal Computer

    HELP Transfer Results to a Personal Computer Replace the Batteries CAUTION: Do not attempt to perform a blood glucose test when 1. Before replacing your batteries, the C ONE meter is connected to a computer. turn off your meter. ONTOUR 2.
  • Page 30: Technical Information

    TECHNICAL INFORMATION Error Detection Displays WARNING The meter screen displays error codes (E plus a number) for test result errors, strip errors, or system errors. When an error occurs, the meter Keep batteries away from children. Many types of batteries beeps 2 times and displays an error code.
  • Page 31: Customer Service Checklist

    TECHNICAL INFORMATION Customer Service Checklist Error Code What it Means What to Do When speaking with the Diabetes Care Customer Service Move the meter, strip, and representative: Too Hot to Test Control control solution to a cooler 1. Have your Solution area.
  • Page 32: Technical Information

    TECHNICAL INFORMATION Technical Information: Accuracy Table 3: System accuracy results for glucose concentrations between 2.0 mmol/L and 35.7 mmol/L The C ONE blood glucose monitoring system was tested ONTOUR with capillary blood samples from 100 subjects. Two replicates were Within ± 0.83 mmol/L or ± 15% tested with each of 3 lots of C test strips for a total of ONTOUR...
  • Page 33: Contour ® Next One Blood Glucose Monitoring System

    TECHNICAL INFORMATION User Accuracy Radar Plot If a data point is at the centre, there is zero error, which means the BGMS reading is identical to the laboratory value. The data points inside the bold green outer circle represent readings within ±...
  • Page 34: Symptoms Of High Or Low Blood Glucose

    TECHNICAL INFORMATION Intermediate measurement precision (which includes variability across High blood glucose (Hyperglycaemia): multiple days) was evaluated using control solutions at 3 glucose • frequent urination • increased fatigue levels. With each control solution, each of 3 lots of C ONTOUR •...
  • Page 35: Specifications

    TECHNICAL INFORMATION Specifications Symbols Used Test Sample: Capillary and venous whole blood The following symbols are used throughout the product labeling for the C ONE blood glucose monitoring system (meter Test Result: Referenced to plasma/serum glucose ONTOUR packaging and labeling, and reagent and control solution packaging Sample Volume: 0.6 L and labeling).
  • Page 36 TECHNICAL INFORMATION References Symbol What it Means 1. Wickham NWR, et al. Unreliability of capillary blood glucose in peripheral vascular disease. Practical Diabetes. 1986;3(2):100. Recycle Packaging 2. Atkin SH, et al. Fingerstick glucose determination in shock. Batteries must be disposed of in accordance with laws in Annals of Internal Medicine.
  • Page 37: Warranty

    TECHNICAL INFORMATION Warranty 5. Ascensia Diabetes Care makes no warranty regarding the performance of the C ONE meter or test results when ONTOUR Manufacturer’s Warranty: Ascensia Diabetes Care warrants to the used with any control solution other than C control ONTOUR original purchaser that this instrument will be free from defects in solution.
  • Page 38: Index

    Index Time ..................38 Specifications ................... 60 After Meal Marker ............4, 19, 20, 29, 30 Symptoms of High or Low Blood Glucose ........58 Alternative Site Testing (AST) ............25 Target Ranges (Before Meal, After Meal, Overall) ......42 Batteries .................
  • Page 39 ONTOUR supplier of this product is authorized to grant such a license. Ascensia, the Ascensia Diabetes Care logo, Contour, Glucofacts, and Second-Chance are trademarks and/or registered trademarks of Ascensia Diabetes Care Holdings AG. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries.

Table of Contents

Save PDF