A1LB, A2LB, and A5LB Test Procedures

Using the codes listed in
enabled). A tester at the customer premises can activate CLOC or CREM loopbacks.
Following
Table 21
is a step-by-step test procedure for verifying the integrity of the HDSL2 channels at every
module location as well as the DS1 channels to the customer and the local DSX-1 interface.
Table 21. Addressable Repeater Loopback Commands (A1LB, A2LB, A5LB)
Loopback
ARMING or NI LPBK (inband)
ARMING or NI LPBK (ESF Data Link)
IR LPDN or DISARM (inband)
IR LPDN or DISARM (ESF Data Link)
IOR LPBK
(NLOC or CREM 230-232 bit errors
(b)
and 229-231 bit errors)
ILR-2 LPBK
(c)
(20 bit errors)
IR LPDN (except SMJK)
IR QUERY LPBK
IR ALTERNATE QUERY LPBK
TIME-OUT OVERRIDE
FAR END NI ACTIVATE (A1LB and
(d)
A2LB only)
IOR POWER DOWN (H2TU-C)
(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
on the facility. The entire arming and loopback sequence can also be initiated at the remote H2TU-R location.
(b) The H2TU-R identifies CREM (and the H2TU-C identifies NLOC) with 231 bit errors, excluding the frame bits. When framed
data is being sent in the AUTO framing mode, the number of the 231 bit errors detected by the test set varies from 229 to 231,
depending on whether or not the test set counts frame errors as bit errors, and on the number of frame bits contained in the
block of 231 error bits. The H2TU-R and H2TU-C generate this bit pattern in a series of discontinuous bursts containing 20-bit
errors each, excluding frame bits. Those test sets that do not count frame error bits as data bit errors will indicate fewer bits than
the H2TU-R and H2TU-C transmit for a CI and NI loopback.
(c) The H2TU-R is assigned the ILR-2 loopback code. It responds with 20 bit errors (excluding the frame bits).
(d) Allows the NIU Activate Command that originates at the H2TU-R to pass through uninhibited toward the network and is always
enabled. No option to disable.
(e) The IOR Power Down code must remain present for the duration of the powerdown mode. When this code is removed, the
HiGain system returns to its normal unlooped and unarmed state.
H2TU-C-231 List 1F
Table
21, a network tester can activate NLOC or NREM loopbacks (or SMJK, if
(a)
(Hexadecimal
Binary Code
Equivalent)
11000-11000 ...
1111-1111-0100-1000 (FF48)
11100-11100 ...
1111-1111-0010-0100 (FF24)
1101-0011-1101-0011 (D3D3)
1100-0111-0100-0010 (C742)
1001-0011-1001-0011 (9393)
1101-0101-1101-0101 (D5D5)
1101-0101-1110-1010 (D5EA)
1101-0101-1101-0110 (D5D6)
1100-0101-0101-0100 (C554)
(e)
0110-0111-0110-0111 (6767)
October 2, 2000
Description
Arming code
Arming code
Disarming code
Disarming code
NLOC—DSX-1 signal is looped back to the network at
the H2TU-C.
CREM—Signal from customer is looped back to the
customer at the H2TU-C.
NREM—DSX-1 signal is looped back to the network at
the H2TU-R.
CLOC—Signal from customer is looped back to the
customer at the H2TU-R.
Loopdown (H2TU-C or H2TU-R)
Query loopback
Alternate query loopback
Loopback time-out override
Unblock AIS
Removes HDSL2 line power
-3
Testing
Bit Error Rate (BER)
55