Page 1
HiGain HiGain UICK NSTALLATION UIDE HMS-318 HMS-317 HMS-317 List 2 and HMS-318 List 2 Product Catalog: 150-1128-02, 150-1129-02 CLEI: T1MFUR04, T1MFVS04...
Page 2
In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other...
Page 3
Unpack each container and inspect the contents for signs of damage. If the equipment has been damaged in transit, immediately report the extent of damage to the transportation company and to ADC DSL Systems, Inc. Order replacement equipment, if necessary.
Page 4
Unpack and Inspect Your Shipment 100-317-102-04, Issue 4 July 26, 1999 HMS-317 List 2 and HMS-318 List 2...
100-317-102-04, Issue 04 Table of Contents ABLE OF ONTENTS Overview _______________________________________________ 1 Product Descriptions..............1 Shelf Connections ..............2 DSX-1 and HDSL Connections Using Plug In Connectors..3 DSX-1 and HDSL Wire Wrap Connectors......3 Management Asynchronous Ports ........... 3 Multishelf Network Connector ..........
Page 6
List of Figures 100-317-102-04, Issue 04 IST OF IGURES 1. Front Views of HMS-317 and HMS-318 ..........1 2. Rear View of the HMS-317 ..............2 3. Rear View of the HMS-318 ..............2 4. HLU Slot Pinouts on the HMS Backplane ..........6 5.
Page 7
100-317-102-04, Issue 04 List of Tables IST OF ABLES 1. J30/J24 - OS RS-232 PORT (DTE) ............4 2. J31/J25 - AUX RS-232 PORT (DTE)............ 4 3. HMS-317 and HMS-318 Connectors ............. 5 4. P1-DSX Receive, Tip and Ring ............11 5.
Page 8
List of Tables 100-317-102-04, Issue 04 July 26, 1999 HMS-317 List 2 and HMS-318 List 2...
100-317-102-04, Issue 4 Overview VERVIEW ® This practice provides installation instructions for the HiGain Management Shelf, HMS-317 List 2 and the HMS-318 List 2. RODUCT ESCRIPTIONS The HMS-317 and HMS-318 shelves (Figure 1) are 5.22 inches high x 12 inches deep (13.26 cm x 30.48 cm) exclusive of mounting brackets. The brackets have adjustable mounts that allow the shelf penetration to conform to existing equipment.
Overview 100-317-102-04, Issue 4 Both connectors and wire-wrap pins are provided for connecting to the DSX/G.703 and HDSL spans (see “Signal and Pin Assignments” on page 11). HELF ONNECTIONS Each shelf provides power (TB1) and alarm (TB2) connections, with backplane communications between the HMU slot and the other card slots (Figure 2 Figure Connector (P2)
100-317-102-04, Issue 4 Overview DSX-1 HDSL C ONNECTIONS SING ONNECTORS The rear of each shelf includes four male 50-pin (HMS- 318) or 64-pin (HMS-317) Amphenol-type connectors for DSX/G.703 (P1 and P2) and HDSL Span (P3 and P4). These provide Tip and Ring connections for all cards in the shelf.
Overview 100-317-102-04, Issue 4 Table 1. J30/J24 - OS RS-232 PORT (DTE) Pin No. Signal Direction Transmit Data (TD) Receive Data (RD) Data Set Ready (DSR) Ground (GND) — Data Terminal Ready (DTR) The HMU-319 requires that DSR be asserted by the connected DCE for communications on this port.
100-317-102-04, Issue 4 Overview ULTISHELF ETWORK ONNECTOR Two backplane connectors, J32 on the HMS-317 and J26 on HMS-318, are available for chaining the management ports of up to 32 shelves together over an integrated LAN. Two other connectors, J34 on both figures, provide a 10BASE-2 and a 10BASE-T (IEEE.802.3) Ethernet LAN (see Figure 2 Figure 3 on page...
Overview 100-317-102-04, Issue 4 Figure 4 shows the line unit slot pinouts on the HMS backplane. DS1/G.703TX-T DS1/G.703TX-R DS1/G.703RCV-R DS1/G.703RCV-T ERR ALM BUS HDSL1-T HDSL1-R MNRALM (LOS ALM)** NMABUS -48VBAT FRAMEGND HDSL2-T HDSL2-R FL (NOT USED) FUSE ALARM* * FUSE ALARM IS NORMALLY FLOATING (0 TO-80V MAX) AND AT-48V (10 MA MAX) WHEN ACTIVATED ** MINOR ALARM OUTPUT IS NORMALLY FLOATING (0 TO -60V MAX) AND AT GND (10 MA MAX, +5 VDC for HLU-319 List 2D) WHEN ACTIVATED...
Page 15
100-317-102-04, Issue 4 Overview Figure 5 shows a typical CO bay layout using the shelves. Heat baffles should be added between every other shelf to help reduce the chimney heating effect. Fuse Panel BAFFLE (HENDRY #02164-02) 28 Line Units + HMU-319 28 Line Units + HMU-319 BAFFLE (HENDRY #02164-02) 28 Line Units + HMU-319...
Installation 100-317-102-04, Issue 4 NSTALLATION This section contains site requirements and installation instructions for the HMS-317 List 2 and the HMS-318 List 2. EQUIREMENTS Each bus should be fused at 10 Amperes. The following two busses provide the -48 V shelf battery feed: •...
100-317-102-04, Issue 4 Installation Wire-wrap the DSX/G.703 and HDSL inputs to the appropriate individual card slots. Pin assignments are listed in “Signal and Pin Assignments” on page Connect the power and optional fan inputs to TB1 as shown in Figure Slots 1 through 14 on the HMS-317 (slots 1 through 11 on the HMS-318) are powered by the -48VA bus, and slots 15 through 28 on the HMS-317 (slots 12 through 22 on the HMS-318) are powered by the -48VB bus.
Installation 100-317-102-04, Issue 4 Connect the optional alarm outputs to TB2 as shown in Figure CRIT CRIT Figure 7. Terminal Strip TB2, HMU-319 Alarm Outputs Install the line units and the HMU-319 management unit in the shelf, as described in the applicable practices (see “Appendix B - Product Support”...
100-317-102-04, Issue 4 Installation IGNAL AND SSIGNMENTS This section includes the following tables of signal and pin assignments. • Table 4, “P1-DSX Receive, Tip and Ring,” on page • Table 5, “P2-DSX Transmit, Tip and Ring,” on page • Table 6, “P3-HDSL Loop 1, Tip and Ring,” on page •...
Page 20
Installation 100-317-102-04, Issue 4 Table 4. P1-DSX Receive, Tip and Ring (Cont.) Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number July 26, 1999 HMS-317 List 2 and HMS-318 List 2...
Page 21
100-317-102-04, Issue 4 Installation Table 5. P2-DSX Transmit, Tip and Ring Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number A (Tip) 1 (Ring) HMS-317 List 2 and HMS-318 List 2 July 26, 1999...
Page 22
Installation 100-317-102-04, Issue 4 Table 5. P2-DSX Transmit, Tip and Ring (Cont.) Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number July 26, 1999 HMS-317 List 2 and HMS-318 List 2...
Page 23
100-317-102-04, Issue 4 Installation Table 6. P3-HDSL Loop 1, Tip and Ring Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number F (Tip) 6 (Ring) HMS-317 List 2 and HMS-318 List 2 July 26, 1999...
Page 24
Installation 100-317-102-04, Issue 4 Table 6. P3-HDSL Loop 1, Tip and Ring (Cont.) Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number July 26, 1999 HMS-317 List 2 and HMS-318 List 2...
Page 25
100-317-102-04, Issue 4 Installation Table 7. P4-HDSL Loop 2, Tip and Ring Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number K (Tip) 9 (Ring) HMS-317 List 2 and HMS-318 List 2 July 26, 1999...
Page 26
Installation 100-317-102-04, Issue 4 Table 7. P4-HDSL Loop 2, Tip and Ring (Cont.) Cable Pin Number Card HMS-317 HMS-318 Slot Pin Number July 26, 1999 HMS-317 List 2 and HMS-318 List 2...
100-317-102-04, Issue 4 Installation Table 8. Standard PIC Color Code Pair Number Ring White Blue White Orange White Green White Brown White Slate Blue Orange Green Brown Slate Black Blue Black Orange Black Green Black Brown Black Slate Yellow Blue Yellow Orange Yellow...
B - P PPENDIX RODUCT UPPORT ADC Customer Service Group provides expert pre-sales and post-sales support and training for all its products. Technical support is available 24 hours a day, 7 days a week by contacting the ADC Technical Assistance Center (TAC).
Appendix C - Abbreviations 100-317-102-04, Issue 4 C - A PPENDIX BBREVIATIONS Customer Interface CLEI Common Language Equipment Interface Central Office CREM Customer Remote Loopback Digital Data Service DSX-1 DS-1 Cross-connect frame Equipment Catalog Item HDSL High-bit-rate Digital Subscriber Line HiGain Doubler Unit HiGain Line Unit HiGain Management Shelf...
Page 31
ADC’s entire liability for software that does not comply with the foregoing warranty and is reported to ADC during the 90-day warranty period is, at ADC’s option, either (a) return of the price paid or (b) repair or replace of the software.
Page 32
ADC DSL Systems, Inc. 14402 Franklin Avenue Tustin, CA 92780-7013 Tel: 714.832.9922 Fax: 714.832.9924 Technical Assistance Tel: 800.638.0031 Tel: 952.917.3222 Fax: 714.730.2400 ISO 9001/TL 9000 DNV Certification, Inc. REGISTERED FIRM : 100-317-102-04, SSUE OCUMENT ´,9*¶9!¨ 1225109...