Summary of Contents for PMFoundations ER-808 Closed Hat Module
Page 1
ER-808 – Assembly Guide _____________________________________________________________________________________ PM Foundations ER-808 v1.4 Closed Hat Module _____________________________________________________________________________________ Page 1 of 5...
Page 2
ER-808 – Assembly Guide _____________________________________________________________________________________ Resistors Arrange the resistors by value on the workbench in the same order as listed in the BOM and install each numbered part for that value before moving onto the next. Install the resistors on the TOP of the board. Take care not to mix up resistors which have similar color codes.
Page 3
ER-808 – Assembly Guide _____________________________________________________________________________________ Electrolytic capacitors Install on the TOP. Make sure you orient correctly. The longer lead and/or the lead marked with a + needs to be inserted into the hole that has the “+” marking near it. Leads marked with “-“ go in the board hole WITHOUT the “+”.
Page 5
ER-808 – Assembly Guide _____________________________________________________________________________________ Testing Install the ICs. Plug the module into the Bus PCB. Connect the L and R outputs of the Trigger/Output module to an amplifier or other listening device in your rack. Power on. Press the button to light and then build a pattern of steps (see User Guide). Start the sequence.