if Sprayer is not properly cleaned and lubricated immediately after every use.
Clean and lubricate Sprayer immediately to prevent permanent damage.
TO PREVENT SERIOUS INJURY:
Do not spray flammable or combustible liquids in a confined area. Spray area must be well
ventilated. Do not smoke while spraying or spray where sparks or flame is present.
Do not use bleach or halogenated hydrocarbon solvents (DCM, 1,1,1– trichloroethane, methyl
bromine, carbon tetrachloride, and ethyl iodide). Long term exposure to many chlorinated
hydrocarbons through inhalation can result in liver and kidney toxicity. Exposure of unprotected
skin to the solvents used can cause defatting of the skin resulting in dermatitis. Methylene chloride
and vinyl chloride have also been shown to be human carcinogens. Some of these solvents are
flammable. Welding operations near the these materials can create phosgene, a highly toxic gas.
Wear ANSI-approved safety goggles, NIOSH-approved respirator, and heavy-duty work gloves during use.
Before First Use - Pre-Cleaning
WARNING! TO PREVENT SERIOUS INJURY: Only water-based materials
or materials with a minimum flash point of 38°C (100°F) should be used for
spraying and cleaning.
Fluid used to test Sprayer before shipping must be flushed out before first use.
1. Lock Trigger and remove battery.
WARNING! TO PREVENT SERIOUS INJURY: TO
PREVENT FIRE: When using mineral spirits, use
only conductive metal pails placed on a grounded
(concrete) surface. DO NOT use plastic containers.
CAUTION! To prevent high pressure solvent or
paint splatter, remove Nozzle Guard and Spray Tip.
2. Designate 1 gallon container for waste.
3. Remove Paint Cup.
4. Insert clean Cup Liner.
5. Fill Cup Liner a quarter-full with mineral spirits.
6. Replace Paint Cup.
7. Open Air Bleed Valve, squeeze Liner until
reservoir inside Air Hole is filled with mineral spirits.
Air
Hole
Air Bleed
Valve
8. Close Air Bleed Valve.
9. Attach battery and unlock Trigger.
Item 58520
RETURNS NOT ACCEPTED & WARRANTY VOID
Only use mineral spirits for pre-cleaning.
For technical questions, please call 1-888-866-5797.
10. Prime:
a. Open Prime/Spray Valve.
b. Turn Sprayer upside-down, press
Trigger for 2 seconds.
c. Close Prime/Spray Valve.
11. Clean Sprayer:
a. Turn Sprayer upside-down, pointing into waste
container, press Trigger until solvent is gone.
Hold Spray Valve against edge of grounded
metal waste container to ground Spray Gun.
b. Refill Cup Liner with solvent and repeat cleaning
process as necessary until solvent is clear.
c. Lock Trigger and remove battery.
d. Remove Paint Cup and let parts dry completely.
NOTE: Dispose of solvent, paint and waste
according to local hazardous waste standards.
Waste