Rohde & Schwarz RTM3K-COM4 Getting Started
Rohde & Schwarz RTM3K-COM4 Getting Started

Rohde & Schwarz RTM3K-COM4 Getting Started

Hide thumbs Also See for RTM3K-COM4:

Advertisement

Quick Links

®
R&S
RTM3000
Oscilloscope
Getting Started
(=Sèâ2)
1335908402
Version 07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RTM3K-COM4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rohde & Schwarz RTM3K-COM4

  • Page 1 ® R&S RTM3000 Oscilloscope Getting Started (=Sèâ2) 1335908402 Version 07...
  • Page 2 ® This manual describes the following R&S RTM3000 models: ● R&S ® RTM3002 (1335.8794K02) ● R&S ® RTM3004 (1335.8794K04) © 2022 Rohde & Schwarz GmbH & Co. KG Muehldorfstr. 15, 81671 Muenchen, Germany Phone: +49 89 41 29 - 0 Email: info@rohde-schwarz.com Internet:...
  • Page 3: Table Of Contents

    ® Contents R&S RTM3000 Contents 1 Safety and regulatory information........5 1.1 Safety instructions................5 1.2 Labels on the product.................11 1.3 Warning messages in the documentation........12 1.4 Where to find key documents on Rohde & Schwarz....... 12 1.5 Korea certification class A..............13 2 Documentation overview............
  • Page 4 ® Contents R&S RTM3000 4.1.2 Other connectors on the front panel............. 23 4.2 Side view....................24 4.3 Rear view..................... 25 5 Contacting customer support..........27 Getting Started 1335.9084.02 ─ 07...
  • Page 5: Safety And Regulatory Information

    ® Safety and regulatory information R&S RTM3000 Safety instructions Safety and regulatory information The product documentation helps you to use the product safely and efficiently. Follow the instructions provided here and in the Chapter 1.1, "Safety instructions", on page 5. Intended use The R&S RTM3000 oscilloscope is designed for measurements on circuits that are only indirectly connected to the mains or not connected at all.
  • Page 6 ® Safety and regulatory information R&S RTM3000 Safety instructions Using the product requires specialists or specially trained personnel. These users also need sound knowledge of at least one of the languages in which the user interfaces and the product documentation are available. Never open the casing of the product.
  • Page 7 ® Safety and regulatory information R&S RTM3000 Safety instructions Setting up the product Always place the product on a stable, flat and level surface with the bottom of the product facing down. If the product is designed for different positions, secure the product so that it cannot fall over.
  • Page 8 ® Safety and regulatory information R&S RTM3000 Safety instructions ● Only use intact cables and route them carefully so that they cannot be dam- aged. Check the power cables regularly to ensure that they are undamaged. Also ensure that nobody can trip over loose cables. ●...
  • Page 9 ® Safety and regulatory information R&S RTM3000 Safety instructions tweezers or pliers to avoid injuries. When transporting the accessories, always use the box supplied with the probe. ● Prevent the probe from receiving mechanical shock. Avoid putting excessive strain on the probe cable or exposing it to sharp bends. Touching a broken cable during measurements can cause injuries.
  • Page 10 ® Safety and regulatory information R&S RTM3000 Safety instructions ● The following effects can cause burns and fire or damage to the measurement site: – Eddy current loss can cause heating of the sensor head. – Dielectric heating can cause heating of cord insulation and other materials. Measurement categories IEC 61010-2-030 defines measurement categories that rate instruments on their ability to resist short transient overvoltages that occur in addition to the working...
  • Page 11: Labels On The Product

    ® Safety and regulatory information R&S RTM3000 Labels on the product Cleaning the product Use a dry, lint-free cloth to clean the product. When cleaning, keep in mind that the casing is not waterproof. Do not use liquid cleaning agents. Meaning of safety labels Safety labels on the product warn against potential hazards.
  • Page 12: Warning Messages In The Documentation

    ® Safety and regulatory information R&S RTM3000 Where to find key documents on Rohde & Schwarz Warning messages in the documentation A warning message points out a risk or danger that you need to be aware of. The signal word indicates the severity of the safety hazard and how likely it will occur if you do not follow the safety precautions.
  • Page 13: Korea Certification Class A

    ® Safety and regulatory information R&S RTM3000 Korea certification class A Korea certification class A 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하 시기 바라며, 가정외의 지역에서 사용하는 것을 목적으로 합니다. Getting Started 1335.9084.02 ─ 07...
  • Page 14: Documentation Overview

    ® Documentation overview R&S RTM3000 Manuals and instrument help Documentation overview This section provides an overview of the R&S RTM3000 user documentation. Manuals and instrument help You find the manuals on the product page at: www.rohde-schwarz.com/manual/rtm3000 Getting started manual Introduces the R&S RTM3000 and describes how to set up the product. A printed English version is included in the delivery.
  • Page 15: Data Sheet And Brochure

    ® Documentation overview R&S RTM3000 Release notes and open source acknowledgment Service manual Describes the performance test for checking the rated specifications, module replacement and repair, firmware update, troubleshooting and fault elimination, and contains mechanical drawings and spare part lists. The service manual is available for registered users on the global Rohde &...
  • Page 16: Preparing For Use

    ® Preparing for use R&S RTM3000 Unpacking and checking Preparing for use Here, you can find basic information about setting up the instrument for the first time or when changing the operating site. Lifting and carrying See: "Lifting and carrying the instrument" on page 6.
  • Page 17: Choosing The Operating Site

    ® Preparing for use R&S RTM3000 Setting up the product Choosing the operating site Specific operating conditions ensure proper operation and avoid damage to the product and connected devices. For information on environmental conditions such as ambient temperature and humidity, see the data sheet. See also "Choosing the operating site"...
  • Page 18: Mounting The Product In A Rack

    ® Preparing for use R&S RTM3000 Setting up the product 2. CAUTION! The top surface of the product is too small for stacking. If you stack another product on top of the product, the stack can fall over and cause injury.
  • Page 19: Considerations For Test Setup

    ® Preparing for use R&S RTM3000 Considerations for test setup To mount the R&S RTM3000 in a rack 1. Use an adapter kit that fits the dimensions of the R&S RTM3000 to prepare the instrument for rack mounting. For information on the dimensions, see data sheet.
  • Page 20: Connecting To Power

    ® Preparing for use R&S RTM3000 Connecting to power Signal input and output levels Information on signal levels is provided in the data sheet. Keep the signal levels within the specified ranges to avoid damage to the product and connected devi- ces.
  • Page 21: Changing Fuses

    ® Preparing for use R&S RTM3000 Changing fuses The required ratings are listed next to the AC power connector and in the data sheet. Changing fuses If the product does not start, it is possible that a blown fuse is the cause. The product is protected by a fuse of type Size 5x20 mm, 250V~, T3.15H (slow- blow), IEC60127-2/5.
  • Page 22: Instrument Tour

    ® Instrument tour R&S RTM3000 Front view Instrument tour Front view Figure 4-1 shows the front panel of the R&S RTM3000. The function keys are grouped in functional blocks to the right of the display. Figure 4-1: Front panel of R&S RTM3000 with 4 input channels 1 = Display 2 = Horizontal and vertical setup controls 3 = Trigger settings, action and analysis controls...
  • Page 23: Input Connectors

    ® Instrument tour R&S RTM3000 Front view The R&S RTM3002 has 2 input channels, and the R&S RTM3004 has 4 input channels. 4.1.1 Input connectors BNC inputs (4 and 5) The R&S RTM3000 has two or four channel inputs (4) to connect the input sig- nals.
  • Page 24: Side View

    ® Instrument tour R&S RTM3000 Side view [Pattern Generator] (8) Connectors for the pattern generator P0, P1, P2, P3. [Probe Comp.] (9) Probe compensation terminal to support adjustment of passive probes to the oscilloscope channel. Square wave signal for probe compensation. Ground connector for probes.
  • Page 25: Rear View

    ® Instrument tour R&S RTM3000 Rear view Logic probe The connectors for logic channels can be used if the Mixed Signal Option R&S RTM-B1 is installed. The option provides connectors for two logical probes with 8 digital channels each (D0 to D7 and D8 to D15). The maximum input voltage is 40 V (peak) at 100 kΩ...
  • Page 26 ® Instrument tour R&S RTM3000 Rear view 5 = Kensington lock slot to secure the instrument against theft 6 = Loop for lock to secure the instrument against theft 7 = not used [Aux Out] (1) Multi-purpose BNC output that can function as pass/fail and trigger output, and output of 10 MHz reference frequency.
  • Page 27: Contacting Customer Support

    ® Contacting customer support R&S RTM3000 Contacting customer support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz product, contact our customer support center. A team of highly qualified engineers provides support and works with you to find a solution to your query on any aspect of the operation, program- ming or applications of Rohde &...

This manual is also suitable for:

Rtm3000

Table of Contents