4. Determine the hex value from the "Decimal to Hex to ASCII Conversion Chart"
later in this chapter for the prefix or suffix you wish to enter.
5. Scan the 2-digit hex value from the "General Programming Chart" in Appendix B.
Repeat Steps 4 and 5 for every prefix or suffix character.
To add the Code I.D., scan 5, C, 8, 0.
To add AIM I.D., scan 5, C, 8, 1.
To add a backslash (\), scan 5, C, 5, C.
6. Scan Save to exit and save, or scan Discard to exit without saving.
7. Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example
Add a Suffix to a specific symbology using Visual Menu.
To send a CR (carriage return) Suffix for UPC only
1. Start Visual Menu.
2. Click the Data Formatting button. The Prefix/Suffix Data Formatter Control dialog
box appears.
2. Click Add.
3. Select UPC from the drop down list and click Next.
4. Select Suffix and click Next.
5. Click Control Characters, double-click CR (carriage return), and click OK.
6. Click Finish and click OK.
7. Click the Write Settings to Device button.

Clearing One or All Prefixes or Suffixes

You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology.
When you Clear One Prefix (Suffix), the specific character you select is deleted from
the symbology you want. When you Clear All Prefixes (Suffixes), all the prefixes or
suffixes for a symbology are deleted.
To clear one or all prefixes or suffixes using Visual Menu
1. Start Visual Menu.
2. Click the Data Formatting button (
dialog box appears.
Programming the 147X
). The Prefix/Suffix Data Formatter Control
3