Operating Instruction; Data Hold - Mastech MS8211D Instruction Manual

Table of Contents

Advertisement

3.2.3 Resistance
Range
Resolution
200Ω
0.1Ω
2KΩ
0.001KΩ
20KΩ
0.01KΩ
200KΩ
0.1KΩ
2MΩ
0.001MΩ
20MΩ
0.01MΩ
- Open Circuit Voltage: 0.25V
- Overload Protection: 250V DC or rms AC
3.2.4 Continuity
Range
Function
Built-in buzzer will sound, if resistance
is lower than 50Ω.
- Open circuit voltage: approx. 0.5V
- Overload Protection: 250V DC or rms AC
3.2.5 Diode
Range Resolution
Display :read approximate
0.001V
forward voltage of diode
- Forward DC Current: approx. 1mA
- Reversed DC Voltage: approx.1.5V
- Overload Protection: 250V DC or rms AC
Accuracy
± (1.0% of rdg + 3 digits)
± (1.0% of rdg + 1 digits)
± (1.0% of rdg + 5 digits)
Function
09
3.2.6 DC Current
Range Resolution
20mA
0.01mA
± (1.5% of rdg +3 digits)
200mA
0.1mA
- Overload Protection: Resettable fuse.
3.2.7 AC Current
Range Resolution
20mA
0.01mA
± (2.0% of rdg +3 digits)
0.1mA
200mA
- Overload Protection: Resettable fuse.
- Frequency Range: 40Hz-200Hz
- Response: Average, calibrated in rms of sine wave.
3.2.8 Logic Test
Range
Description
0V
1.5V
Low "0"
Logic
Green
LED on
-Input Impedance: approx. 1MΩ- Overload
Protection: 250V DC or rms AC

4. OPERATING INSTRUCTION

4.1 Data Hold

If you need data hold when measuring, you can put on
"DATA-H" button, it will hold the reading; if you put the
button again, data hold is not continue.
Accuracy
Accuracy
3.5V
5V
High "1"
Green, Red
Red LED
LED off
on
10

Advertisement

Table of Contents
loading

Table of Contents