TYPE OF GAS
GAS INPUT
BCX-14G/AA
Natural
Steam - 50,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 115,000 BTU/Hr
Propane
Steam - 48,000 BTU/Hr
Hot Air - 65,000 BTU/Hr
Total - 113,000 BTU/Hr
BX-14G/AA and CNVX-14G/AA
Natural
Hot Air - 65,000 BTU/Hr
Propane
Hot Air - 65,000 BTU/Hr
3/4" NPT connector for all U.S. and Canadian installations
VOLTAGE
HZ
208
60
240
60
480
60
ELECTRICAL RATINGS - GAS OVENS
BCX-14G/AA, BX-14G/AA AND CNVX-14G/AA
VOLTAGE
115
208-240
115
208-240
115
208-240
115
208-240
RATINGS - ELECTRIC APPLIANCES
BCX-14E/AA, BX-14E/AA AND CNVX-14E/AA
KW
PHASE
19
3
19
3
19
3
PHASE
AMPS
1
12
1
6
1
12
1
6
1
12
1
6
1
12
1
6
MAX LOAD (AMPS
L1
L2
L2
53
53
50
46
46
43
23
23
21
3
Installation
Owner's Responsibilities
MOTOR
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
3/4 HP 208-240VAC, 3 phase,
50/60 Hz
MOTOR
3/4 HP 208-240VAC, 50/60 Hz
3/4 HP 208-240VAC, 50/60 Hz
3/4 HP 208-240VAC, 50/60 Hz