SmartTouch 2™ Control
1. With the oven off, the control displays the POWER
screen. Press the TOOLS key.
2. On the TOOLS MENU press the MANAGER key.
3. Press the PRIME DELIME PUMP key on the display.
4. Press and hold the PRIME key. Watch for deliming
solution to flow through the tube. When the delime
solution has reached the barbed fitting on the back of
the oven, release the key.
5. The pump is now primed. Press the EXIT key.
6. Press the BACK key two times. The control returns to
the POWER screen.
Deliming System Connection and Priming (BCX-14 units only)
Figure 9
11