Troubleshooting

Troubleshooting
Important: It is essential that all operator safety mechanisms be connected and in proper operating
condition prior to mower use.
The following table lists some of the common causes of trouble. If assistance is needed, contact your
Exmark Service Dealer.
Problem
Discharge gate does not open and/or close.
Foot pedal is too loose or tight.
Grass or debris is escaping by discharge gate.
Possible Cause
1. Discharge gate is deformed.
2. Discharge gate is not adjusted properly.
3. Cable is disconnected at one or both ends.
4. Grass or debris may be caught near the
accessory mounting pin or discharge
opening.
1. Pivot bolt and nut not adjusted properly.
1. Discharge gate may be worn.
2. Gate is not closing properly.
16
Corrective Action
1. Reshape the discharge gate.
2. Adjust the cable nuts and/or pivot gate.
3. Reconnect cable.
4. Remove grass and debris.
1. Adjust the bolt and nut for proper
resistance.
1. Replace discharge gate.
2. See Troubleshooting item "Discharge
gate does not open and/or close".