SETTING THE MAIN MENU AND WELDING PARAMETERS
After the SAW power supply is turned on, the control panel starts to work. If there is no error in the
system, the main menu appears on the display. The main menu contains the following sections.
1. Wire speed (cm/minute),
2. Welding voltage,
3. Tractor feed speed,
4. Welding current,
5. Number of welding wires,
6. Welding wire diameter,
7. Program number (0-9).
SETTING THE WIRE SPEED
In the stop position (when welding has not started), the wire speed can be regulated using the keypad.
It can be increased or decreased by using the
described below.
SETTING THE WIRE SPEED WHEN WELDING IS NOT STARTED
When welding is not started, the wire speed on the screen is selected by pressing the
the control panel. The selection is indicated by the
be entered using the keypad (keys 1-9). The entered values flash during the entry. The entered values
are accepted by pressing the
the newly pressed values.
and
symbol. In this case, the new wire speed can
key again. Pressing the
8
12/2021 Rev. 1.0
keys while welding. The operation is
key during the entry process cancels
button on