Error codes or messages

Note:
Message: 0175: Bad CRC1, stop POST task
Solution: The EEPROM checksum is not correct (block #6). Have the
computer serviced.
Message: 0187: EAIA data access error
Solution: The access to EEPROM is failed. Have the computer serviced.
Message: 0188: Invalid RFID serialization information area or bad CRC2.
Solution: The EEPROM checksum is not correct (block # 0 and 1, or block #
6). The system board should be replaced, and the box serial number needs to
be reinstalled. Have the computer serviced.
Message: 0189: Invalid RFID configuration information area
Solution: The EEPROM checksum is not correct (block # 4 and 5). The system
board should be replace, and the UUID needs to be reinstalled. Have the
computer serviced.
Message: 0190: Critical low-battery error
Solution: The computer turned off, because the battery is low. Connect the ac
adapter to the computer and charge the battery, or replace the battery with a
fully charged one.
Message: 0193: RF antenna has been removed
Solution: The RFID antenna that you installed has been removed. Enter the
supervisor password to return your computer to the normal operation.