Connecting The Cooktop To The Mains Power Supply - Fisher & Paykel CI304DTB Installation Manual

Hide thumbs Also See for CI304DTB:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT!
This cooktop must be connected to the mains power supply only by a suitably qualified person.
To connect the cooktop to the mains power supply, do not use adapters, reducers, or
branching devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 165
o
F / 75
Before connecting the cooktop to the mains power supply check that:
The domestic wiring system is suitable for the power drawn by the cooktop.
The voltage corresponds to the value given in the rating plate (refer Step 11 for location).
The power supply cable sections can withstand the load specified on the rating plate.
Power supply
CI122DTB*
MAX.
MAX.
VOLTAGE
CURRENT
LOAD
DRAW
208V
14A
3400W
240V
16A
3840W
*The CI122DTB comes supplied with a cable. This must be wired into a suitably rated plug, permanent connection outlet or power isolator.
IMPORTANT!
Check with an electrician whether the domestic wiring system is suitable without alterations. Any
alterations must only be made by a qualified electrician.
!1
FIT CLAMPING BRACKETS BASED ON THE
COUNTERTOP THICKNESS
No. of brackets and slot positions depends on model
Rating plate location
(bottom of chassis)
1/2"-1 1/4"
(12-40mm)
Fit a minimum of 2 brackets on opposing sides
!0

CONNECTING THE COOKTOP TO THE MAINS POWER SUPPLY

o
C at any point.
CI244DTB
CI304DTB
MAX.
MAX.
MAX.
CURRENT
CURRENT
LOAD
DRAW
DRAW
26A
6400W
28A
6500W
30A
7400W
32A
7400W
view from below
1 1/4"+
(40mm+)
Connection diagrams
CI244DTB, CI304DTB, CI365DTB
CI365DTB
MAX.
MAX.
MAX.
CURRENT
LOAD
LOAD
CI122DTB
DRAW
39A
9600W
45A
11000W
3 wire cable
from power supply
Junction box
Red wires
Black wires
White wire
Green & Yellow wire
CSA or UL - listed
conduit connector
3 wire cable
from power supply
Junction box
Red wire
White wire
Black wires
Green & Yellow wire
CSA or UL - listed
conduit connector
!2
SECURE TO COUNTERTOP
4 wire cable
from power supply
Junction box
Red wires
White wire
Black wires
Green & Yellow wires
CSA or UL - listed
conduit connector
4 wire cable
from power supply
Junction box
Red wire
White wire
Black wires
Green & Yellow wires
CSA or UL - listed
conduit connector
Secure on at least 2
opposing sides
Repeat on all the other brackets