IMPORTANT!
This cooktop must be connected to the mains power supply only by a suitably qualified person.
●
To connect the cooktop to the mains power supply, do not use adapters, reducers, or
●
branching devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
●
temperature will not exceed 165
o
F / 75
Before connecting the cooktop to the mains power supply check that:
The domestic wiring system is suitable for the power drawn by the cooktop.
●
The voltage corresponds to the value given in the rating plate (refer Step 11 for location).
●
The power supply cable sections can withstand the load specified on the rating plate.
●
Power supply
CI122DTB*
MAX.
MAX.
VOLTAGE
CURRENT
LOAD
DRAW
208V
14A
3400W
240V
16A
3840W
*The CI122DTB comes supplied with a cable. This must be wired into a suitably rated plug, permanent connection outlet or power isolator.
IMPORTANT!
Check with an electrician whether the domestic wiring system is suitable without alterations. Any
alterations must only be made by a qualified electrician.
!1
FIT CLAMPING BRACKETS BASED ON THE
COUNTERTOP THICKNESS
No. of brackets and slot positions depends on model
Rating plate location
(bottom of chassis)
1/2"-1 1/4"
(12-40mm)
Fit a minimum of 2 brackets on opposing sides
!0
CONNECTING THE COOKTOP TO THE MAINS POWER SUPPLY
o
C at any point.
CI244DTB
CI304DTB
MAX.
MAX.
MAX.
CURRENT
CURRENT
LOAD
DRAW
DRAW
26A
6400W
28A
6500W
30A
7400W
32A
7400W
view from below
1 1/4"+
(40mm+)
Connection diagrams
CI244DTB, CI304DTB, CI365DTB
CI365DTB
MAX.
MAX.
MAX.
CURRENT
LOAD
LOAD
CI122DTB
DRAW
39A
9600W
45A
11000W
3 wire cable
from power supply
Junction box
Red wires
Black wires
White wire
Green & Yellow wire
CSA or UL - listed
conduit connector
3 wire cable
from power supply
Junction box
Red wire
White wire
Black wires
Green & Yellow wire
CSA or UL - listed
conduit connector
!2
SECURE TO COUNTERTOP
4 wire cable
from power supply
Junction box
Red wires
White wire
Black wires
Green & Yellow wires
CSA or UL - listed
conduit connector
4 wire cable
from power supply
Junction box
Red wire
White wire
Black wires
Green & Yellow wires
CSA or UL - listed
conduit connector
Secure on at least 2
opposing sides
Repeat on all the other brackets
8