Cisco 5000 Series Hardware Installation Manual page 61

Platform and switch
Hide thumbs Also See for 5000 Series:
Table of Contents

Advertisement

Chapter 2
Cisco Nexus 5000 Series Overview
S e n d d o c u m e n t a t i o n c o m m e n t s t o n x 5 0 0 0 - d o c f e e d b a c k @ c i s c o . c o m
Table 2-8
Power Supply Condition
Power supply warning events where the power supply
continues to operate. These events include high
temperature, high power, and slow fan.
AC present, 3.3 voltage standby (VSB) on, and the power
supply unit is off.
Power supply on and OK.
If you haveone power supply installed in the chassis, but the other power supply slot is empty, you
should use a blank filler panel to cover the empty slot.
panel.
Figure 2-35
Fan Modules
The Cisco Nexus 5010 switch has slots for two fans modules. Each fan module houses six fans. If you
insert 2 fan modules (with 6 fans in each module), your switch will have a total of 12 fans.
shows the fan module.
OL-15902-01
Power Supply LED Descriptions (continued)
Blank Power Supply Filler Panel
Power LED Status
Off
1 Hz blinking
On
Figure 2-35
shows a blank power supply filler
Cisco Nexus 5000 Series Hardware Installation Guide
Cisco Nexus 5010 Switch
Fail LED Status
Blinking
Off
Off
Figure 2-36
2-29