When the setback is set to ON, the motor for angle driving is braked after the monitor angle voltage reaches the
previous angle memory, and then the motor for anteroposterior driving is rotated to the storage direction in low
speed. After that, if LIFTPULSE changes from L to H, the motor for anteroposterior driving is stopped.
Explanation on FLAP storage operation
In six seconds after ACC is turned OFF when CLOSE key is pressed or the automatic opening and closing
setting is ON, the motor for angle driving is rotated to 0° direction.
When the setback is set to ON, the motor for anteroposterior driving is rotated to the discharge direction in high
speed and the motor is continuously rotated for 600 ms after LIFTSW changes from H to L, and then the motor
for angle driving is rotated to 0° direction.
The motor for angle driving is rotated to 0° direction for 900 ms after DEG0SW changes from H to L and the
imposition operation is carried out.
900 ms later, the motor for angle driving is braked and the motor for anteroposterior driving is rotated to the
storage direction.
After the horizontal operation status detection pulse is detected 15 times, the motor for anteroposterior driving is
rotated to the storage direction in low speed.
If the horizontal operation status detection pulse cannot be detected for 600 ms, the brake is operated and the