5
Check 2: Check RF level
<Check>
Check the "ASMAX value" on the test mode screen in the focus closed status in the test mode.
NO.
Disc used
1
GGV1025
2
TCD-782
ASMAX value:
00000045 in this case
Check 3: Check measured values of error ratio
<Check>
Check the error ratio of a specified ID in the tracking closed status in the test mode.
NO.
Disc used
1
GGV1025
2
GGV1025
3
TCD-782
Error ratio:
0.742E-5 in this case
5
6
Spot to check
Rated value
ASMAX value on
0000 0026 or more
test mode screen
ASMAX value on
0000 0029 or more
test mode screen
Spot to check
Rated value
ID : 40000
1.000E-3 or less
ID : 200000
1.000E-3 or less
ID : Home position
2.500E-3 or less
AVH-P6300BT/XNUC
6
7
RF level requiring gain + 6dBup
(check)
RF level requiring gain + 6dBup
(check)
Remarks:
7
8
Remarks:
(ASMAX level)
(ASMAX level)
8
A
B
C
D
E
F
39