MULTIQUIP LT6KV Operation Manual page 41

Light tower/generator
Table of Contents

Advertisement

When performing any maintenance on the light tower
or engine, follow all safety messages and rules for safe
operation stated at the beginning of this manual.
GENERAL INSPECTION
Prior to each use, the light tower should be cleaned and
inspected for deficiencies. Check for loose, missing or
damaged nuts, bolts or other fasteners. Also check for
fuel or oil leaks.
WARNING
Accidental starts can cause severe injury or
death.
ALWAYS place the ON/OFF switch in the
OFF position.
Disconnect negative battery cable from
battery before servicing.
WARNING
Some maintenance operations may
require the engine to be run. Ensure
that the maintenance area is well
ventilated. Exhaust contains poisonous
carbon monoxide gas that can cause
unconsciousness and may result in
DEATH
CAUTION
ALWAYS allow the engine to cool
before servicing. NEVER attempt any
maintenance work on a hot engine.
LT6KV LIGHT TOWER • OPERATION MANUAL — REV. 2 (07/08/16) — PAGE 41
AIR CLEANER
NOTICE
If engine is operating in very dusty and dry grass
conditions, a clogged air cleaner will result in high fuel
consumption, loss of power and excessive carbon
buildup in the combustion chamber.
Thoroughly remove dirt and oil from the engine and
surrounding area. Clean or replace the air cleaner
elements as necessary. Check and retighten all fasteners
as necessary.
1. Release the locking latch and remove the air filter paper
element as shown in (Figure 26).
Figure 26. Air Cleaner Components
2. Clean the inside of the cover using a damp cloth.
3. Blow dry with compressed air 30 psi (207 kPa, 2.1 kgf/cm
maximum against the side of the paper filter element
(Figure 27) along the pleats. Then blow dry against
outside along the pleats, then against inside again.
PAPER
FILTER
ELEMENT
Figure 27. Cleaning Inner Paper Filter
MAINTENANCE
)
2

Advertisement

Table of Contents
loading

Table of Contents