STORAGE
For storage for over 30 days, the following is required:
Fill the fuel tank completely and treat with a diesel fuel
stabilizer.
Completely drain oil from the crankcase and refill if
necessary with fresh oil.
Clean the entire light tower.
Disconnect the negative terminals of the battery and
cover it, or remove and store it separately. If necessary
keep battery charged.
If the ambient temperature is expected to drop below
0°C (32°F), add antifreeze to the radiator.
Cover the light tower and store in a clean, dry place away
from children and unauthorized personnel.
LT6KV LIGHT TOWER • OPERATION MANUAL — REV. 2 (07/08/16) — PAGE 47
REMOVAL FROM LONG TERM STORAGE
If light tower is going to be used again after long term
storage, perform the following.
Apply oil to the engine valve and rocker arms, and examine
the operating condition of the valves.
Change the oil in engine oil pan.
Replace all the filters.
Flush the inside of the cooling system.
Drain the water from the fuel tank and bleed the air from the
fuel system.
If the engine has not been started for more than one year,
contact your Kohler distributor to have engine overhauled.