STORAGE
For storage for over 30 days, the following is required:
„ Fill the fuel tank completely and treat with a diesel fuel
stabilizer.
„ Completely drain oil from the crankcase and refill if
necessary with fresh oil.
„ Clean the entire light tower.
„ Disconnect the negative terminals of the battery and
cover it, or remove and store it separately. If necessary
keep battery charged.
„ If the ambient temperature is expected to drop below
0°C (32°F), add antifreeze to the radiator.
„ Cover the light tower and store in a clean, dry place away
from children and unauthorized personnel.
LT6KV LIGHT TOWER • OPERATION MANUAL — REV. 2 (07/08/16) — PAGE 47
REMOVAL FROM LONG TERM STORAGE
If light tower is going to be used again after long term
storage, perform the following.
„ Apply oil to the engine valve and rocker arms, and examine
the operating condition of the valves.
„ Change the oil in engine oil pan.
„ Replace all the filters.
„ Flush the inside of the cooling system.
„ Drain the water from the fuel tank and bleed the air from the
fuel system.
„ If the engine has not been started for more than one year,
contact your Kohler distributor to have engine overhauled.
MAINTENANCE