3. Wiring the Power Inputs

The Upper Panel of the Industrial Managed Switch indicates an inlet power
socket and consists of one green terminal block connector within 6 contacts. Please
follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or
Contacts 5 and 6 for Power 2.
 DC 9-48V, AC 24V
2. Tighten the wire-clamp screws for preventing the wires from loosening.
Figure 3-2: Power1 & 2 Pins of Terminal Block Connector
1. The wire gauge for the terminal block should be in the range
from 12 to 24 AWG.
2. Please check the AWG Ampere specification before connecting
Note
PLANET Industrial Managed Switch.
DI0
DI1 DO0 DO1
1 2 3 4 5 6
Max. Fault Alarm Loading: 24V, 1A
1 2 3 4 5 6
V1+
DC Input: 9-48V
, 4A max.
AC Input: 24V
, 2A max.
PWR1
Figure 3-1: IGS-6325-5X1T Upper Panel
1
2
3
V1+
V1-
Power 1
GND
GND
V2+
Alarm
PWR2
4
5
6
V2+
V2-
Power 2
5