    LH1 Heated Breathing Tube User Manual Table of Contents 1. Device Symbols ...................... 1 2. Warning, Caution and Important Tip ............... 2 3. Intended Use ......................2 4. Specifications ......................3 5. Features ......................... 4 6. First Time Setup ..................... 4 6.1 Connecting the Heated Breathing Tube to the Device........
  • Page 3: Device Symbols

    LH1 Heated Breathing Tube User Manual 1. Device Symbols Manufacturer Follow Instructions for Use Operating Instructions Type BF Applied Part DC Power IPX2 Dripping (15º tilted) Lot number Do not use the product if the package is damaged WEEE Marking Use-by date Logo of BMC Medical Co., Ltd.
  • Page 4: Warning, Caution And Important Tip

    Warnings, Cautions, and Important Tips appear throughout this manual as they apply. 3. Intended Use The LH1 Heated Breathing Tube (Heated Breathing Tube for short) is heated air tubing intended for incorporation into respiratory therapy devices and humidifiers with conical ISO connectors (ISO 5356).
  • Page 5: Specifications

    LH1 Heated Breathing Tube User Manual 4. Specifications Inner Diameter 19 mm The length under static (unstressed) condition in the horizontal plane is 1.8 m Length Margin of Error: ±10% Transport Operation Storage 5°C ~ 35°C -25°C ~ 70°C Temperature Environmental 15% ~...
  • Page 6: Features

    (hereinafter referred to as breathing gas supply device) produced or authorized for use by BMC or recommended by prescription doctor. The use of incorrect breathing gas supply device may affect the the effectiveness of the treatment.
  • Page 7: Connecting The Heated Breathing Tube To The Device

    LH1 Heated Breathing Tube User Manual CAUTION! • Check the integrity of the product packaging, if the package is found damaged, please do not use this product. • When using the product, make sure that patients are closely monitored. • Check the product regularly and replace the product immediately if it is found to be contaminated or no longer applicable to its use intention.
  • Page 8: Removing The Heated Breathing Tube From The Device

    LH1 Heated Breathing Tube User Manual Power connector socket on the breathing gas supply device Fig. 6-1 (4) Connect the mask connector of Heated Breathing Tube and mask. CAUTION! • Before each use of the product, test the product according to the instructions of the device manufacturer to ensure that the product is compatible with the device and that the product is free of air leakage and blockage.
  • Page 9: Cleaning The Heated Breathing Tube

    • No sterilization is required by the product. CAUTIONS! • BMC has used the following disinfectants to verify the disinfection cycle of the Heated Breathing Tube, and the number of cycles of verified disinfection is 100 times. • Disinfectants generally damage the surface of materials and shorten the service life of the product.
  • Page 10: Disposal

    9. Technical Support Please contact BMC directly if you need the technical documents of the Heated Breathing Tube for certain purposes such as maintenance or connection to other equipment. BMC will provide the technical documents in whole or in part according to your needs.
  • Page 11 LH1 Heated Breathing Tube User Manual Guidance and manufacturer's declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The user of the device should make sure that it is used in such an environment.
  • Page 12 LH1 Heated Breathing Tube User Manual Guidance and manufacturer's declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The user of the device should make sure that it is used in such an environment.
  • Page 13 LH1 Heated Breathing Tube User Manual Recommended separation distances between portable and mobile RF communications equipment and the device The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference...
  • Page 14: Limited Warranty

    (3) months from the date of sale by BMC Medical Co., Ltd. to the dealer. If the product fails to perform in accordance with the product specifications, BMC Medical Co., Ltd. will repair or replace, at its option, the defective material or part. BMC Medical Co., Ltd.
  • Page 15 391937...

Table of Contents