6.10) Replacement of the Lubridryer pads
Open the Lubridryer by unlatching and unscrew the (4) thumbscrews. Remove the two lubridryer bushings.
Remove the used Lubridryer pad by sliding them up the channel. Discard of the used pads properly. Insert new
pad by sliding the pads down the channel, install the bushing and thumbscrews. Replace the bushings when
excessively worn.
Thumbscrews
Bushing
Pads
Shown used pads
Shown one set of screws,
New pads installed
bushing and pad
Figure 23 Lubridryer Components
6.11) Lubrication of cable
NOTE
Use oil only as per the hoist manufacturer's recommendations.
The Lubridryer includes a reservoir that can be filled with oil. The reservoir can be used to store spare Lubridryer
pads. The Lubridryer includes a valve that shuts off the flow of oil when not in use.
When oil is added to the reservoir and the valve is open the oil seeps through a small hole to lubricate the rear
pad. The front pad should be soaked in oil before installing it, open the oil reservoir and dip the pads into the oil
filled reservoir. Therefore, it is recommended to always keep a spare set of pads in the reservoir of oil to use as
the next set. Wipe excess oil off of the frame and use a clean cloth to keep the oil off of the capstans when the
RHGSE is not in use.
Oil reservoir
Airline connection
Air outlet
Shut off valve
Valve
Figure 24 Lubrication Valve
Figure 25 Compressed Air attachment
6.12) Performing a fresh water wash
Fill the rotating tub ¾ of the way with fresh water and extend the cable all the way down. Using a hose, rinse off
the helicopter hoist and the cable between the helicopter hoist and the rotatub. If shop air is available, attach an
airline to the Lubridryer via the quick disconnect nipple supplied with the RHGSE.
Run the
(See section 6.13)
hoist in the up direction with the load brake applied. Before operating with water rotate the load adjuster counter
clock wise to reduce the load to approximately 100 lbs. carefully observe the cable at all times on the capstans.
Retract the entire cable out of the Rotatub, and position the drum so that the plug is above the hole in the frame
then remove the plug at the bottom and drain into an approved drain.
.
This manual contains proprietary information and is not to be copied or disclosed without written permission from Zephyr International LLC
Page 18 of 38
Copyright 2002-2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZGS-11000-2 v2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents