Clean the housing at least once a month with a soft vacuum cleaner brush. If there is a high amount of
dust, weekly cleaning is recommended! Dust and dirt can impair the function of the built-in sensor!
This product is only suited for indoor-use and not for outdoor-use!
For groups of people who cannot perceive the alarm, for example because they are hard of hearing or
sleep very deeply, the installation of a heat detector is not sufficient. In this case, take further measures to
ensure that these people are also warned in the event of a fire!
The remodeling of this product is not allowed! The proper and safe functioning of the device can no longer
be guaranteed if it is modified! In addition, this will invalidate the warranty claim!
The manufacture does not accept any responsibility for injuries or damage resulting from improper use of
this product!
Any other use than the description may result in damage to the product. So the dangers are such as
electric shock, short circuit, fire etc.
We reserve the right to make changes to the product, the packaging or the operating instructions as well as
printing errors.
Protect the product from external damage, heavy dirt, moisture and excessive heat!
In order that the warranty claim does not expire please use only the supplied items. Repairs may only be
done by an expert and only by using original spare parts!
Recommended installation locations for heat detector:
Rooms with high humidity, e.g. in the bathroom
Kitchens. In the kitchen should be installed a heat detector should only if the distance to the stove is at least
4m.
Bedrooms: Install a device in every bedroom!
Corridors: Install a device in each corridor that leads to a bedroom. If the corridor is longer than 9m, install a
device at the beginning and end of the corridor.
Stairwell: Install a heat detector on each floor in the stairwell.
Living and working rooms as well as storage areas.
Cellar. Mount a device in the entrance area to the basement.
Rooms with electrical equipment
Attics: When installing heat detectors on pitched roofs, ensure a minimum distance of 0.5m-1m from the top
of the roof (see Figure 4).
Attics with horizontal ceiling: see Figure 5 for installation
Mount heat detectors at least 0.5m away from lamps!
Install several devices in large corridors or large rooms. Observe a maximum distance of 15m!
Install heat detectors in narrow corridors or rooms no larger than 1m wide in the middle of the ceiling.
Unsuitable mounting locations for heat detectors:
Heat detectors should not be installed near heating, cooling- and ventilation shafts.
On ceiling beams that are lager than 0.2m
Near open fires or fireplaces
In very dusty rooms.
On A-shaped roofs, the heat detector must not be mounted at the highest point.
In caravans or rooms with a low ceiling height.