Countermeasures; Changing The Fuse - Mitsubishi Heavy Industries TU1250SAE Operation Manual

Table of Contents

Advertisement

Countermeasures

Surely follow the instructions of this operation manual
for the countermeasures of the troubles.

Changing the fuse

Use the designated fuse.
Surely stop the operation of refrigeration unit with
the "Operation switch" and set the "Main switch" to
"OFF", then disconnect the battery terminal and plug
for power cord to change the fuse.
F12
F2
F2
F4
F8
F6
F9
F7
CAUTION
CAUTION
F11
F1 : 20 A (operation circuit) is xed with the fuse holder.
F2 : 15 A (Relay circuit)
F3 : 10 A (Compressor electromagnetic clutch)
F4 : 10 A (Drain hose heater A)
F5 : 15 A (Evaporator fan motor 1)
F6 : 15 A (Evaporator fan motor 2)
F7 : 15 A (Evaporator fan motor 3)
F1
F8 : 15 A (Evaporator fan motor 4)
F9 : 30 A (Throttle solenoid)
F10 : 10 A (Output during operation)
F11 : 10 A (Output at error occurrence)
F12 : 10 A (Output at deviation from adequate temperature)
F10 F3
F5
F1 fuse holder
- 72 -