Refrigeration System; Ambients; Clearances; Electrical Specifications - Follett REF20-LB Installation, Operation And Service Manual

Table of Contents

Advertisement

Refrigeration System

The REF20/25 series refrigeration system is designed to give many years of trouble-free service . Except for routine
cleaning of the air-cooled condenser and related parts, the refrigeration system requires no service or maintenance .
The system uses a capillary tube metering device and is critically charged . Access fittings are not provided .
Temporary piercing valves are required to work on the refrigeration system . Follett recommends that if hoses are
ever connected to the refrigeration system for service, the refrigerant should be recovered, permanent access
valves should be installed and the system evacuated, and recharged by weighing in the correct refrigerant charge
(refrigerant R134a, 11 .4 oz (322g) .
Note: Do not charge the system by pressures .

Ambients

Intended for indoor use where ambient temperature, measured at the condenser inlet, does not exceed 80 F
(27 C) and ambient relative humidity does not exceed 60% RH . A heated door is recommended for higher humidity
ambients .

Clearances

The top of the refrigerator must have 10 inches (25 .4 cm) of clear space above the refrigerator to ensure proper
ventilation of the refrigeration system .
The back of the refrigerator should have 1 inch (2 .5 cm) of clearance to allow for power cord clearance on unit and
an additional 1 inch (2 .5 cm) if the unit is to be plugged in directly behind the refrigerator .

Electrical specifications

§ 115 V, 60 Hz, 1 phase
§ Running load amps: 8 .4A without heated door; max 9 .7A with door heater energized 100% (adjustable)
§ Full load amps (90% maximum continuous current per UL 471 at 40 C): 10 .5A
§ Minimum circuit ampacity: 15A dedicated circuit
§ Maximum size of branch circuit overcurrent device: 15A dedicated circuit
§ Follett recommends circuit be protected by GFCI breaker

Refrigeration specifications

§ Refrigerant R134a, 11 .4 oz (322 g)
§ Compressor amperage: RLA - 7 .6A, LRA - 44 .5A
§ Compressor winding resistances: C-S (5 .2Ω - 5 .9Ω), C-R (1 .2Ω - 1 .3Ω)
§ Evaporator fan motor amperage: FLA - 0 .22A
§ Condenser fan motor amperage: FLA - 0 .46A
§ Condenser inlet air temperature: 75 F (23 .9 C)
§ Discharge pressure (psi): 126
§ Suction pressure (psi): 11
4
01134592 – REF20/25 LB, PH, BB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ref25-lbRef20-phRef25-phRef20-bbRef25-bbJ62764

Table of Contents