Annual cleaning

Removal of dust and other particulates from air intake areas and the
condenser is important for proper operation . Environments with large
amounts of dust may require more frequent cleaning .
1. Disconnect power to unit by turning power switch off (located on upper
front facade panel) and removing power cord from receptacle .
2. The condenser can be accessed from top for cleaning . The side
panel in front of condenser may be completely removed for easier
cleaning by disconnecting facade and removing upper side panel .
See Face Removal for facade removal instructions .
3. Inspect drain pan for any debris or obstruction in condensate pan
(Fig. 31.1) .
4. Use a vacuum cleaner with brush attachment to clean condenser,
compressor and related parts .
5. Reinstall upper side panel and facade if removed .

Defrosting

REF20/25 series upright refrigerators do not require manual defrosting . The evaporator defrosts automatically
when the refrigeration unit is in the OFF cycle . The evaporator fan will run continuously .