ELECTRICAL SCHEMATIC

Model 3000

Sheet 1 of 2
A
B
C
02
04
06
ELECTRICAL SUPPLY
480VAC/3PH/60HZ/GND
08
TB1-PE
10
12
14
(8 AWG)
16
18
20
22
24
26
(12 AWG)
28
30
32
34
36
38
40
42
-F22
44
46
L1-5
48
50
L3-5
52
54
56
58
60
62
64
66
68
32
D
E
F
-F11
L1-1
L2-1
L3-1
22 - 32 A
(SET @ 25.7A)
-F13
L1-3
L2-3
L3-3
5.5 - 8
(SET @ 7.2A)
-K62
TB1-19
L1-5A
21
22
TB1-20
-T22
208/230/400/460 VAC PRIMARY
24/120 VAC SECONDARY
100VA
460V
400V
230V
208V
COM
G
H
J
-K62
TB1-1
L1-1A
TB1-2
L2-1A
TB1-3
L3-1A
TB1-PE
28A
-K43
TB1-7
L1-3A
TB1-9
L2-3A
TB1-11
L3-3A
17A
-K45
L1-4A
TB1-13
L2-4A
TB1-15
L3-4A
TB1-17
17A
HEATER 1
27 W
460 VAC
0.06A
CONNECT TO BACKPANEL
TB2-1
N
FU22
FU22.1
FU22.2
24V
5A
PLEASE NOTE:
120V
FOR OPERATION 380-400VAC/3PH/50HZ,
MOVE PRIMARY TO 400VAC TAP.
K
L
M
N
COMPRESSOR 1
460 VAC, 3PH
M
13 HP, 25.7 RLA
FAN 1
1.05 KW
M
460 VAC
1.8 FLA
TB1-PE
FAN 3
1.05 KW
M
460 VAC
1.8 FLA
FAN 2
M
1.05 KW
460 VAC
1.8 FLA
TB1-PE
FAN 4
1.05 KW
M
460 VAC
1.8 FLA
P
Q

Hide quick links: