Modbus Registers
Holding Register
Reference
Address
40001
0x0000
40002
0x0001
40003
0x0002
40004
0x0003
40005
0x0004
40006
0x0005
40007
0x0006
40008
0x0007
40009
0x0008
40010
0x0009
40011
0x000A
40012
0x000B
40013
0x000C
40014
0x000D
40015
0x000E
40016
0x000F
40017
0x0010
40018
0x0011
40019
0x0012
40020
0x0013
40021
0x0014
40022
0x0015
40023
0x0016
40024
0x0017
40025
0x0018
40026
0x0019
40027
0x001A
40028
0x001B
40029
0x001C
40030
0x001D
40031
0x001E
40032
0x001F
40033
0x0020
40034
0x0021
40035
0x0022
40036
0x0023
40037
0x0024
40038
0x0025
40039
0x0026
40040
0x0027
40041
0x0028
40042
0x0029
40043
0x002A
40044
0x002B
40045
0x002C
40046
0x002D
40047
0x002E
40048
0x002F
40049
0x0030
40050
0x0031
40051
0x0032
40052
0x0033
40053
0x0034
40054
0x0035
10
Name
DRYER_STATUS
ALARM_STATUS
WARNING_STATUS
RESERVED
SERVICE_TIMER
TOTAL_TIMER
EVAPORATOR_INLET_TEMP
DISCHARGE_TEMP
DRYER_LOAD
SAVINGS
EVAPORATOR_OUTLET_TEMP
DRYER_MODEL
DRYER_MODE
SERVICE_INTERVAL
AUTO_RESTART
UI_LANGUAGE
RESERVED
RESERVED
ENERGY_COST
AUDIBLE_ALARM
MODBUS_ADDRESS
FULL_POWER
ALARM_MSG_1
ALARM_MSG_2
INPUT_STATUS
OUTPUT_STATUS
ANALOG[0]
ANALOG[1]
ANALOG[2]
PV
P
I
D
FIXED_LOAD
FIXED_UNLOAD
FIXED_TIME
DELTA_PID_CALC
DELTA_PID_CTRL
Units
Status ID
Status ID for the dryer
Flag Bits
Alarm flag bits
Flag Bits
Warning flag bits
N/A
Reserved
Hours
Timer to service
Hours
Total operating hours
1/10 Degree Celsius
Evaporator inlet temperature
1/10 Degree Celsius
Discharge temperature
%
Dryer load
Dollars / Euros
Energy savings
1/10 Degree Celsius
Evaporator outlet temperature
Model_ID
Dryer model
Mode_ID
Dryer mode
Hours
Service interval
Boolean
Auto-restart (0=Disabled, 1=Enabled)
Language_ID
User interface language
N/A
Reserved
N/A
Reserved
Integer
Energy cost (Cost / kWh)
Boolean
Audible Alarm (0=Disabled, 1=Enabled)
Integer
Modebus Address
Watts
Full load power
Integer
Alarm message #1 phrase id
Integer
Alarm message #2 phrase id
Flag Bits
Digital Input Status
Flag Bits
Digital Output Status
1/10 Degree Celsius
Analog Input [0]
1/10 Degree Celsius
Analog Input [1]
1/10 Degree Celsius
Analog Input [2]
1/10 Degree Celsius
Process value
Integer
P Term
Integer
I Term
Integer
D Term
Seconds
Fixed cycle load period
Seconds
Fixed cycle unload period
Seconds
Fixed mode timeout period
1/10 Degree Celsius
PID calculation set point
1/10 Degree Celsius
PID control set point
Description