Model 1500 - Gardner Denver RNC Series Instruction Manual

Refrigerated type compressed air dryers
Hide thumbs Also See for RNC Series:
Table of Contents

Advertisement

ELECTRICAL SCHEMATIC

Model 1500

Sheet 1 of 2
A
B
C
02
04
ELECTRICAL SUPPLY
06
480VAC/3PH/60HZ/GND
TB1-PE
08
10
12
14
(12 AWG)
16
18
20
22
24
26
(12 AWG)
28
30
32
34
36
38
40
42
44
46
-F22
48
50
L1-5
52
54
L3-5
56
58
60
62
64
66
68
28
D
E
F
-F11
L1-1
L2-1
L3-1
11-16 AMP
(SET @ 12.9A
-F13
L1-3
L2-3
L3-3
2.8 - 4 AMP
(SET @ 3.6A)
L1-3
L2-3
L3-3
-K62
TB1-19
L1-5A
21
22
TB1-20
-T22
208/230/400/460 VAC PRIMARY
24/120 VAC SECONDARY
100VA
460V
400V
230V
208V
COM
G
H
J
-K62
TB1-1
L1-1A
TB1-2
L2-1A
TB1-3
L3-1A
TB1-PE
17A
-K43
TB1-7
L1-3A
TB1-9
L2-3A
TB1-11
L3-3A
17A
-K45
TB1-13
L1-4A
TB1-15
L2-4A
TB1-17
L3-4A
17A
HEATER 1
27 W
460 VAC
0.06A
CONNECT TO BACKPANEL
TB2-1
N
FU22
FU22.1
FU22.2
24V
5A
PLEASE NOTE:
FOR OPERATION 380-400VAC/3PH/50HZ,
120V
MOVE PRIMARY TO 400VAC TAP.
K
L
M
N
COMPRESSOR
M
460 VAC, 3PH
7HP, 12.9 RLA
FAN 1
M
1.05 KW
460 VAC
1.8 FLA
TB1-PE
FAN 2
M
1.05 KW
460 VAC
1.8 FLA
TB1-PE
SHT#2 4N
SHT#2 4B
P
Q

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rnc1000Rnc1250Rnc1500Rnc1750Rnc2000Rnc2500 ... Show all

Table of Contents