152-202-115-04, Revision 04
A
PPENDIX
Power
Line Voltage
CO Supply
Electrical Protection
Fusing
Environmental
Operating Temperature
Operating Humidity
Physical
Height
Width
Depth
Weight
Mounting
HDSL2
Line Code
Transmission
Media
Output
Line Impedance
Maximum Provisioning Loss
Start-up Time
DSX-1
DSX-1 Line Impedance
DSX-1 Pulse Output
DSX-1 Input Level
System
One-way DS1 Delay
Wander (Looped)
Wideband Jitter (Looped)
Narrowband Jitter (Looped)
H2TU-C-202 List 1E
A - S
PECIFICATIONS
0, -185 Vdc
-48 Vdc nominal (-42.5 to -56.5 Vdc)
(See
"Power Consumption"
Current Drain" on page
Secondary surge and power cross protection on HDSL2 ports. Requires external
primary protection.
Internal; connected to FUSE ALARM output on pin 25
-40 °F to +149 °F (-40 °C to +65 °C)
5% to 95% (non-condensing)
5.6 in. (14.22 cm)
0.7 in. (1.7 cm)
5.6 in. (14.22 cm)
1 lb., 2 oz. (.51 kg)
200 and 400 mechanics
1.552 Mbps OPTIS
Full duplex
One non-loaded, copper, two-wire cable pair
+16.8 dBm ±0.5 dB at 135 Ω (0-450 kHz) at CO side;
+16.5 dBm ±0.5 dB at 135 Ω (0-350 kHz) at remote side
135 Ω
35 dB at 196 kHz
30 sec. (typical), 1 min. (maximum) per span
100 Ω
pk-pk
6 V
pre-equalized for 0-655 feet of ABAM cable
+1.5 to -7.5 dB DSX
<400 µs per span without regenerators
Meets MTIE T1.101 requirements
0.2 UI maximum
0.1 UI maximum
April 21, 2000
and
"Maximum Power Dissipation"
52.)
Appendix A - Specifications
and
"Maximum
51
Need help?
Do you have a question about the HiGain H2TU-C-202 and is the answer not in the manual?
Questions and answers