ADC HiGain H2TU-C-202 User Manual page 26

Hide thumbs Also See for HiGain H2TU-C-202:
Table of Contents

Advertisement

Provisioning
Table 6
lists the Config screen PairGain Options and describes their available settings. Selections in bold typeface
are the factory default settings.
Table 6. H2TU-C-202 List 1E Config Screen PairGain Options
PairGain Options
Screen Code Settings
(a)
Line Power Feed
PWRF
Remote Provisioning
RTPV
Bipolar Violation
BPVT
Transparency
See
"Bipolar Violation
Transparency (BPVT)
Option" on page
20.
HDSL2 BER
HBER
Threshold
See
"HDSL2 BER
(HBER) Option" on
page 19
and
"System
Alarm Output Pins"
on page
54.
DS1 BER
DBER
Special Loopback
SPLB
Mode
SmartJack Loopback
LPBK
Minor Alarm
ALM
Network AIS Signal
NAIS
H2TU-R DS1 Frame
CONV
Conversion
See
"H2TU-R DS1
Frame Conversion
(CONV) Option" on
page
20.
18
Description
OFF
Disables powering to the HDSL2 pair.
ON
Keeps the HDSL2 line voltage at the nominal -185 Vdc.
ENA
Enables remote provisioning.
DIS
Disables remote provisioning.
ENA
Enables BPVs and HDSL2 CRC errors at the DS1 input to be converted
into DS1 BPVs at the DS1 output at the distant end. This makes HiGain
HDSL2 transparent to BPVs.
DIS
Disables BPV Transparency.
1E-6
System alarm relay contact closes and the Status LED flashes red when
the Block Error Rate exceeds 10
definition of Bit Error Rate.)
1E-7
System alarm relay contact closes and the Status LED flashes red when
BER exceeds 10
NONE
Prevents generation of a system alarm due to BER.
ENA
Enables the fixed 24-hour T1 BER threshold.
DIS
Prevents the generation of a system alarm due to T1 BER.
GNLB
Configures the HiGain HDSL2 system to respond to the generic inband
loopback codes.
A2LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Teltrend addressable repeater.
A3LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom addressable repeater.
A4LB
Configures the HiGain HDSL2 system to respond to the inband loopback
codes of the Wescom Mod 1 addressable repeater.
ENA
Enables the HiGain HDSL2 system to recognize all inband SmartJack
loopback commands.
DIS
Configures the HiGain HDSL2 system to ignore all inband SmartJack
loopback commands.
ENA
Enables the generation of the output alarm on pins 22 and 30 when a
system alarm condition occurs.
DIS
Disables the generation of the output alarm on pins 22 and 30 when a
system alarm condition occurs.
CI
If ALMP is set to AIS, this option specifies which pattern is sent to the
network when a remote LOS or AIS occurs. When configured for CI, an
AIS-CI pattern is sent to the network. For priority resolution, see
on page
41.
AIS
When configured for AIS, an AIS pattern is sent to the network.
OFF
Framing determined by the DS1 frame formatting option.
ACON
Auto (ACON) detection of framing and potential frame conversion at the
remote.
FCON
Auto detection of framing and forced frame format conversion (FCON) at
the H2TU-R.
April 21, 2000
-6
. (Block Error Rate is based on the
-7
.
152-202-115-04, Revision 04
Figure 25
H2TU-C-202 List 1E

Advertisement

Table of Contents
loading

Table of Contents