OPTIONS AND ACCESSORIES

Remote Control Enclosures — RMB Series
RMB Series remote control enclosures are available in various
configurations for use with strip heaters. Remote control
enclosures locate controls away from the heat of the unit,
increasing the life span of the controls. All models are built in
accordance with CE standards with switches, indicator lights,
and wiring. Consult the factory for type and location of RMB
Series controls for enclosure.
NOTE: RMB Series remote control enclosures require one
remote control enclosure per strip heater.
1. Determine the area to mount the RMB box.
IMPORTANT NOTE:
Remote mounted enclosures and control switches must be
installed in a cool, dry location as far away from any heat zone
as possible. Do not mount enclosures or switches directly on,
under, or above unit. Do not mount enclosures or switches
in direct contact with any heated surface or near any steam
generating equipment.
Dimensions
Width
Depth
Models
(A)
(B)
RMB-3
150 mm
76 mm
Series
(5-15/16")
(3")
RMB-7
239 mm
76 mm
Series
(9-3/8")
(3")
RMB-14
366 mm
76 mm
Series
(14-3/8")
(3")
Top View
A
Front View
D
E
Control Enclosure Dimensions
2. Secure the RMB to the mounting surface using appropriate
screws or fasteners.
• Use the mounting flange on each end of the RMB.
NOTE: Sizing of the power supply wire leads and upstream
overcurrent protection must conform with National
Electric Code (NEC) requirements as well as all local
codes.
3. Remove the wiring access cover on bottom of the control
enclosure by removing screws and sliding cover off.
4. Identify and remove the appropriate knockouts from the
control enclosure for the electrical connections.
Screw
Screw
Height
Width
Height
(C)
(D)
(E)
67 mm
161 mm
41 mm
(2-5/8")
(6-5/16")
(1-5/8")
67 mm
249 mm
41 mm
(2-5/8")
(9-13/16")
(1-5/8")
67 mm
376 mm
41 mm
(2-5/8")
(14-13/16")
(1-5/8")
Side View
B
C
5. Attach conduit connectors to the knockouts in the control
enclosure.
Infinite Control
Toggle Switch
Wiring
Access
Cover
Removing Wiring Access Cover
6. Make the electrical connections between the unit and
the output terminals on the terminal block in the control
enclosure. Refer to the wiring diagrams included with the
unit and the RMB control enclosure.
NOTE: To ground the RMB, use either a separate ground wire,
metallic conduit, or other locally accepted method in
accordance with the National Electric Code (NEC) or
Canadian Electric Code (CEC).
7. Make the electrical connections between the power supply
and the input terminals on the terminal block inside the
control enclosure. Refer to the wiring diagram included
with the RMB control enclosure.
NOTE: Verify which wire leads from the foodwarmer are
for phase, neutral, and/or lighting connections, as
applicable.
8. Make sure all wire connections are tight, and secure both
conduit runs to the conduit connectors.
9. Reinstall the wiring access cover on bottom of the control
enclosure.
10. Turn on power at the fused disconnect switch/circuit
breaker, turn on the unit, and test operation.
20
English
Indicator
Light
Terminal Block
Relay
Knockout
Cover
Screw
Form No. GRM_CN-0818