Appendix A - Specifications - ADC H2TU-C-202 User Manual

List 3f higain line unit
Hide thumbs Also See for H2TU-C-202:
Table of Contents

Advertisement

LTPH-UM-1161-01
A
PPENDIX
Power
HDSL2 Span Voltage
CO Supply
Electrical Protection
Fusing
Environmental
Operating Temperature
Operating Humidity
Physical
Height
Width
Depth
Weight
Mounting
HDSL2
Line Code
Transmission
Media
Output
Line Impedance
Maximum Insertion Loss
Maximum Loop Attenuation
Start-up Time
DSX-1
DSX-1 Line Impedance
DSX-1 Pulse Output
DSX-1 Input Level
System
One-way DS1 Delay
Wander (Looped)
Wideband Jitter (Looped)
Narrowband Jitter (Looped)
H2TU-C-202 List 3F
A - S
PECIFICATIONS
0 or -180 ±5 Vdc
-48 Vdc nominal (-42.5 Vdc to -56.5 Vdc)
See
"Power Consumption"
Current Drain" on page
Secondary surge and power cross protection on HDSL2 ports. Requires external
primary protection.
Internal; connected to "FUSE ALARM" output on pin25
-40°F to +149°F (-40°C to +65°C)
5% to 95% (non-condensing)
5.6 in. (14.22 cm)
0.7 in. (1.7 cm)
5.6 in. (14.22 cm)
1 lb. 2 oz. (.51 kg)
200 and 400 mechanics, high-density shelves
1.552 Mbps Overlapped Pulse Amplitude Modulation Transission with Interlocking
Spectra (OPTIS)
Full duplex
One non-loaded, copper, two-wire cable pair
+16.8 dBm ±0.5 dB at 135Ω (0-450 kHz) at CO side;
+16.5 dBm ±0.5 dB at 135Ω (0-350 kHz) at remote side
135Ω
35 dB at 196 kHz
28 dB
30 sec. typical, 1 min. maximum per span
100Ω
pk-pk
6 V
pre-equalized for 0-655 feet of ABAM cable
+1.5 to -7.5 dB DSX
<400 µs
Meets MTIE T1.101 requirements
0.2 UI maximum
0.1 UI maximum
June 28, 2002
and
"Maximum Power Dissipation"
62.

Appendix A - Specifications

and
"Maximum
61

Advertisement

Table of Contents
loading

Table of Contents