H2Tu-C Ds1 Current Statistics - ADC H2TU-C-202 User Manual

List 3f higain line unit
Hide thumbs Also See for H2TU-C-202:
Table of Contents

Advertisement

LTPH-UM-1161-01
Monitor
Performance
-----------------------------------------------------------------------------
1 Day
Start
00:00
CV-L
420
ES-L
SES-L
UAS-L
76330
CV-P
ES-P
SES-P
UAS-P
B8ZSS
MSEC
83818
-----------------------------------------------------------------------------
Use <Space> to cycle through..
choices and <Enter> to view...
.ID:
Table 13. Error Acronyms Used on the DS1 Performance History Screens
Error
Description
Acronym
CV-L
Code Violation - Line
Total BPV count.
ES-L
Errored Seconds - Line
Seconds with BPV ≥ 1.
SES-L
Severely Errored Seconds - Line
Seconds with BPV plus EXZ ≥ 1544 or
LOS ≥ 1.
UAS-L
Unavailable Seconds - Line
Seconds with LOS ≥ 1.
CV-P
Code Violation - Path
Total count of FE errors for SF or CRC-6 errors for
ESF.
ES-P
Errored Seconds - Path
Seconds with SEF
FE (SF) ≥ 1.
SES-P
Severely Errored Seconds - Path
Seconds with SES, CRC (ESF) ≥ 320, or
(SF) ≥ 8 (F
(g)
FE
(a) Line (L) refers to the AMI DS1 line used to transport the payload.
(b) Appears on H2TU-R Performance History screens.
(c) Appears on the DS1 Current Statistics screens.
(d) Path (P) refers to the total framed payload being transported between two points.
(e) Severely Errored Frame—Two or more frame bit errors occurring in a 0.75 ms interval for SF or a 3 ms interval for ESF.
(f) Appears on the H2TU-R Blockage Indicator (BI) History screen.
(g) FE is a frame bit error.
H2TU-C-202 List 3F
Event Log
Config
H2TU-C DS1
1 Hour
15 Min
23:00
23:15
0
0
3
0
0
0
0
0
1018
118
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1018
118
Press: C(l)ear Current Statistics
Interface
Statistics :
04/10/2002 23:16:58
Figure 17. H2TU-C DS1 Current Statistics
(a)
(d)
(e)
, CRC (ESF), or
+ F
).
T
S
Inventory
Report
Current Statistics
:
H2TU-C DS1
Current
H2TU-C
Error
Description
Acronym
UAS-P
Unavailable Seconds - Path
A second of unavailability based on SES-P or
AIS ≥ 1.
(b)
PRM-NE
Performance Report Monitoring - Near End
The PRM registers in the ESF/FDL from CPE
indicate errors, and the signal received from the
network at the remote is error-free.
(b)
PRM-FE
Performance Report Monitoring - Far End
The PRM registers in the ESF/FDL from the network
indicate errors, and the signal received from the
CPE is error-free.
(c)
B8ZSS
B8ZS Monitored Seconds
Seconds with B8ZS detection when AMI option is
active.
(c)
MSEC
Monitored Seconds of the current
(15-minute/1-hour/1-day) screen.
(f)
BI
Blockage Indicator (BI) = [(0.2 x ES + 0.4 x SES +
UAS)/ MSEC] x 100% (MSEC is the same as the
DS1 MSEC)
June 28, 2002
Monitoring System Activity and Performance
Rlogon
Help
System: Alarm
33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H2TU-C-202 and is the answer not in the manual?

Questions and answers

Table of Contents