Appendix A - Technical Specifications - ADC HiGain HLU-200 List 2D User Manual

Line unit, litespan-2000 channel bank
Hide thumbs Also See for HiGain HLU-200 List 2D:
Table of Contents

Advertisement

150-200-124-02, Issue 2
A
PPENDIX
HDSL
Line Code
Output
Line Impedance
Span Voltage
Start-up Time (per span)
DS-1
Line rate
Line format
Frame format
Line Clock Rate
Internal Stratum 4 clock
One-way DS-1 Delay
<220 µs per span
Maximum Provisioning Loss
35 dB @ 196 kHz, 135Ω
Maximum Heat Dissipation
5W (without doubler), 6.3W (with doubler) typical
Mounting
Litespan 2000 CBA/ONU-48, 96
Electrical Protection
Secondary surge and power cross protection on all HDSL ports.
Environmental
Operating Temperature
Operating Humidity (non-condensing)
Dimensions and Weight
Height
Width
Depth
Weight
HLU-200 List 2D
A - T
ECHNICAL
784 kbps, 2B1Q
+13.5 dBm ±0.5 dB at 135Ω
135Ω
-130 V to ± 200 V dc
30 seconds (typical), 60 seconds (maximum) per span
1.544 Mbps ± 200 bps
AMI, B8ZS, or ZBTSI
ESF, SF or unframed/CRC
-40°F (-40° C) to +149°F (+65°C)
5% to 95% (non-condensing)
4.42 in. (11.22 cm)
0.84 in. (2.13 cm)
10.2 in. (25.9 cm)
1 lb. (.45 kg)
February 10, 1999

Appendix A - Technical Specifications

S
PECIFICATIONS
35

Advertisement

Table of Contents
loading

Table of Contents