Mechanical Installation

___________________________________________________________
Contents of the chapter
This chapter describes the actions needed to assist while installing the drive.
Safety
WARNING! Lift the drive with a lifting device. Use the lifting eyes of the enclosure.
Do not tilt the enclosure.
Checking the installation site
Check the installation site:
The installation site is sufficiently ventilated or cooled to remove heat away from the drive.
The ambient conditions of the drive meet the specifications.
There is enough free space above and around the drive to enable cooling, service, and maintenance.
For floor-mount, the floor that the drive cabinet is installed on is of non-flammable material, as smooth
as possible, and strong enough to support the weight of the unit. Check the floor flatness with a spirit
level. The maximum allowed deviation from the surface level is 5 mm in every 3 meters. Level the
installation site, if necessary, as the cabinet is not equipped with adjustable feet.
Checking the delivery
The drive delivery contains:
Drive cabinet
Option modules (if ordered) installed onto the control unit or into the cabinet at the factory
Appropriate drive, accessories, and option module manuals
Delivery documents
Verify there are no signs of damage. Before attempting installation and operation, check the information on
the type designation labels of the drive to verify that the delivery is of the correct type.
Required tools