1 - INTRODUCTION

CONDENCIAT
CL2 series air-cooled condensation units are outdoor packaged units equipped as standard with:
®
Low-noise scroll compressor.
-
Air-cooled condenser.
-
Axial fan(s) with variable speed control.
-
These are factory tested and supplied with a nitrogen charge.

2 - RECEIPT OF GOODS

Check the unit for any damage or missing components upon delivery. Note any damaged or missing parts on the delivery slip.
IMPORTANT: you must notify the carrier of any damage and/or missing parts by registered letter within three days of the
delivery date.

3 - EQUIPMENT IDENTIFICATION

Each unit has a name plate bearing an identification number.
Please state this number in all correspondence.

4 - WARRANTY

The warranty is effective for a period of 12 months from the date the unit is first commissioned into service, provided said date occurs
within three months of the invoice date.
It is effective for a period of 15 months from the unit invoice date in all other cases.
NOTE: For further information, refer to the application of the CIAT warranty.

5 - SAFETY RECOMMENDATIONS

To protect against accidents while installing, commissioning and adjusting the unit, the following settings must be kept in mind:
Pressurised refrigeration circuit
-
Presence of refrigerant
-
Presence of voltage
-
Site of installation
-
Temperatures up to 150°C
-
Only experienced and qualified persons may work on this equipment. The recommendations and instructions given in the maintenance
brochures and the special instructions on the labels must be followed.
Always comply with applicable standards and regulations.
IMPORTANT: before carrying out any work on the unit, make sure it is powered off.

6 - UNIT LOCATION

The installer must check the following points before handling, placing or connecting the unit:
These units are intended for use outdoors, near a building, on a deck/patio or in a garden. Although it is rain resistant, it may be
-
installed under a shelter with adequate ventilation on all four sides.
The ground or surface on which the unit is placed must be strong enough to support the weight of the unit.
-
Position the unit above the average snow depth for the region where the unit is installed.
-
The unit must be perfectly level.
-
Leave sufficient room around the unit to allow easy access for servicing and maintenance.
-
Sound level: our units are designed to operate quietly. However, as soon as you begin designing your system, you should take into
consideration the outdoor environment in order to estimate the radiated noise and the building type in order to estimate the noise
transmitted through the air and by solid materials (vibrations).
If in doubt, have an analysis performed by an acoustical engineer.