Advertisement

Split Air Conditioner
Model:
GSAF209XAE/XAC GSAF212XAE/XAC
GSAF218XAE/XAC GSAF224XAE/XAC
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
If you have lost the Owner's Manual, please contact the local agent or visit
www.gree.com or sent email to global@gree.com.cn for electronic version.

Advertisement

Table of Contents
loading

Summary of Contents for Gree GSAF209XAE

  • Page 1 GSAF218XAE/XAC GSAF224XAE/XAC Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner’s Manual, please contact the local agent or visit www.gree.com or sent email to global@gree.com.cn for electronic version.
  • Page 2: Table Of Contents

    Content Operation Notices Precautions......................1 Parts Name......................6 ScreenOperation Guide Buttons on remote controller .................8 Introduction for icons on display screen ..............8 Introduction for buttons on remote controller ............9 Function introduction for combination buttons ............15 Operation guide ....................16 Replacement of batteries in remote controller .............16 Emergency operation ..................
  • Page 3 Explanation of Symbols Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 4: Precautions

    Precautions WARNING Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 5 Precautions WARNING Maintenance must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. Do not extend fingers or objects into air inlet or air outlet.
  • Page 6 Precautions WARNING Attachment Installation must be performed by qualified professionals. Otherwise, it may cause personal injury or damage. Must follow the electric safety regulations when installing the unit. According to the local safety regulations, use qualified power supply circuit and circuit break. Do install the circuit break.
  • Page 7 Precautions WARNING Do not put through the power before finishing installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
  • Page 8 Precautions WARNING For the air conditioner with plug, the plug should be reachable after finishing installation. For the air conditioner without plug, an circuit break must be installed in the line. If you need to relocate the air conditioner to another place, only the qualified person can perform the work.
  • Page 9: Parts Name

    Parts Name Indoor Unit air inlet panel aux.button horizontal louver air outlet (Display content or position may be different from above graphics, please refer to actual products) remote control Outdoor Unit air inlet Connection wire air outlet NOTICE: Actual product may be different from above graphics, please refer to actual products.
  • Page 10 Parts name Display (Heating mode Not Applicable) For some model: For some model: temp. indicator cooling power receiver heating indicator indicator window indicator display cooling indicator receiver power heating temp. drying window display indicator indicator indicator indicator drying indicator For some model: drying For some model: indicator...
  • Page 11: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button MODE button FAN button TURBO button ▲/ button button button SLEEP button I FEEL button TIMER ON/TIMER OFF button CLOCK button QUIET button X-FAN button (Note: X-FAN is the same with BLOW.) LIGHT button button TEMP button Introduction for icons on display screen...
  • Page 12: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: ● This is a general use remote controller, it could be used for the air conditioners with multifunction; For some function, which the model doesn't have, if press the corresponding button on the remote controller that the unit will keep the original running status.
  • Page 13 Introduction for buttons on remote controller ● When selecting heating mode, the air conditioner operates under heat mode. Heat indicator " " on indoor unit is ON. Press "▲" or " " button to adjust set temperature. Press "FAN" button to adjust fan speed. Press " "...
  • Page 14 Introduction for buttons on remote controller button (Not applicable) Press this button can select left & right swing angle. Fan blow angle can be selected circularly as below: no display (stops at current position) Note: ● Press this button continuously more than 2s, the main unit will swing back and forth from left to right, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately.
  • Page 15 Introduction for buttons on remote controller this button again within 2s, the change of swing status will also depend on the circulation sequence stated above. SLEEP button Under COOL, HEAT or DRY mode, press this button to start up sleep function. "...
  • Page 16 Introduction for buttons on remote controller Note: ● Under on and off status, you can set TIMER OFF or TIMER ON simultaneously. ● Before setting TIMER ON or TIMER OFF, please adjust the clock time. ● After starting up TIMER ON or TIMER OFF, set the constant circulating valid. After that, air conditioner will be turned on or turned off according to setting time.
  • Page 17 Introduction for buttons on remote controller LIGHT button Press this button to turn off display light on indoor unit. " " icon on remote controller disappears. Press this button again to turn on display light. " " icon is displayed. button Press this button to achieve the on and off of healthy and scavenging functions in LCD displays "...
  • Page 18: Function Introduction For Combination Buttons

    Function introduction for combination buttons Energy-saving function Under cooling mode, press "TEMP" and " CLOCK" buttons simultaneously to start up or turn off energy-saving function. When energy-saving function is started up, "SE" will be shown on remote controller, and air conditioner will adjust the set temperature automatically according to ex-factory setting to reach to the best energy-saving effect.
  • Page 19: Operation Guide

    Function introduction for combination buttons WIFI Function (Not Applicable) Press "MODE" and "TURBO" button simultaneously to turn on or turn off WIFI function. When WIFI function is turned on, the " " icon will be displayed on remote controller; Long press "MODE" and "TURBO" buttons simultaneously for 10s, remote controller will send WIFI reset code and then the WIFI function will be turned on.
  • Page 20: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 21 Clean and Maintenance Clean filter Open panel Clean filter Pull out the panel to a certain ● Use dust catcher or water to angle as shown in the fig. clean the filter. ● When the filter is very dirty, use the water (below 45℃...
  • Page 22 Clean and Maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 23: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution ● Whether it's interfered severely ● Pull out the plug. Reinsert (such as static electricity, stable the plug after about 3min, and voltage)?
  • Page 24 Malfunction analysis Phenomenon Check items Solution ● Power failure? ● Wait until power recovery. ● Is plug loose? ● Reinsert the plug. ● Air switch trips off or fuse is ● Ask professional to replace burnt out? air switch or fuse. Air condit- ●...
  • Page 25 Malfunction analysis Phenomenon Check items Solution ● Whether there’s odour source, ● Eliminate the odour source. Odours are such as furniture and cigarette, emitted ● Clean the filter. etc. ● Whether there’s interference, ● Disconnect power, put back Air conditio- ner operates such as thunder, wireless power, and then turn on the...
  • Page 26 Malfunction analysis Error Code ● When air conditioner status is abnormal, temperature indicator on indoor unit will ation of error code. Above indicator diagram is only Indoor for reference. Please refer to display actual product for the actual indicator and position. Error code Error code Troubleshooting...
  • Page 27: Installation Dimension Diagram

    Installation dimension diagram Space to the wall At least 15cm At least 15cm Space to the wall Drainage pipe...
  • Page 28: Safety Precautions For Installing And Relocating The Unit

    Safety precautions for installing and relocating the unit To ensure safety, please be mindful of the following precautions. Warning When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant. Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture, resulting in injury.
  • Page 29: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: ●...
  • Page 30: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. air switch. 3. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
  • Page 31: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. 3.
  • Page 32 Installation of indoor unit Indoor outdoor Note: ● Pay attention to dust prevention and take relevant safety measures when Φ55/ opening the hole. 5-10 Φ70 ● The plastic expansion particles are not provided and should be bought locally. Step four: outlet pipe 1.
  • Page 33 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench Φ 6 15~20 Φ 9.52 30~40 union nut Φ 12 45~55 pipe Φ 16 60~65 torque wrench Φ 19 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 34 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole of indoor unit and then pull it out from the front side. power connection wire 3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color;...
  • Page 35 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 36: Installation Of Outdoor Unit

    Installation of outdoor unit Step one: fix the support of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: ●...
  • Page 37 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- 3. Pretightening the union nut with dle of outdoor unit and then remove hand. the handle. pipe joint screw union nut handle 2.
  • Page 38 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: ● Never cut the power connection wire to prolong or shorten the distance. Step six: neaten the pipes 1.
  • Page 39: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas liquid valve piezometer valve and the nut of refri- gas valve gerant charging vent. refrigerant charging 2. Connect the charging ho- valve cap vent se of piezometer to the refrigerant charging vent nut of refrigerant...
  • Page 40: Check After Installation

    Check after installation ● Check according to the following requirement after finishing installation. Items to be checked Possible malfunction Has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage It may cause insufficient cooling test? (heating) capacity.
  • Page 41: Configuration Of Connection Pipe

    Configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe. Max. length of connection pipe Unit: m Max. length Max. length Cooling Cooling of connec- of connec- capacity capacity...
  • Page 42 Configuration of connection pipe Additional refrigerant charging amount for R22, R407C, R410A and R134a Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m) Φ6 Φ9.52 or Φ12 Φ6 or Φ9.52 Φ16 or Φ19 Φ12 Φ19 or Φ22.2 Φ16...
  • Page 43: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: A: Cut the pipe E: Expand the port ● Confirm the pipe length according to ● Expand the port with expander. the distance of indoor unit and hard outdoor unit.