Vents-us TwinFresh Expert RW1-50 V.2 User Manual page 14

Single-room reversible energy regeneration ventilator
Hide thumbs Also See for TwinFresh Expert RW1-50 V.2:
Table of Contents

Advertisement

The speed selection sequence is as follows: I-II-III-Standby. All the units integrated in a network run with the speed
set with the Master unit.
I: permanent glowing of the indicator indicates operation of the unit with the first speed. Blinking of the indicator
indicates activation of the
I and II: permanent glowing of the indicators I and II indicates running of the ventilator at the speed II.
I, II and III: permanent glowing of the indicators I, II and III indicates running of the ventilator at the speed III.
Synchronous blinking of the indicators I, II and III indicates activation of the timer in the
off delay timer in the Boost mode in case of actuation of the connected external sensors or integrated humidity
sensor.
Alternate blinking of the indicators I, II and III indicates running of the ventilator at the speed set with the mobile
application using the slider selector for manual speed setting or activation of the scheduler.
Regeneration mode
TwinFresh Expert
Rotation direction of the fan changes once in 70 seconds. Heat regeneration is accomplished in the Regeneration
mode. To enable operation of the ventilators in opposite directions change the position of the DIP switch No. 3.
TwinFresh Expert Duo
Rotation direction of the fans change once in 70 seconds. Heat regeneration is accomplished in the Regeneration
mode.
Ventilation mode
TwinFresh Expert
The ventilator runs in the extract or in the supply mode at the set speed. The fan rotation direction depends on
the position of the DIP switch 3.
TwinFresh Expert Duo
One fan runs in the air extract mode and the other fan runs in the air supply mode at a set speed. The fans do not
change the rotation direction.
No glowing of the indicators
ventilator. This mode may be activated via the mobile application only.
The filter clogging indicator starts blinking 90 days after installation of the cartridge. In this case, clean or replace
the filters (see the "Technical maintenance" section).
Filter
After replacement of the filters reset the filter timer using the mobile application or press and hold the
button on the indoor unit of the Master unit for 5 seconds, until a signal beeps.
Alarm indicator. In case of failure, the
Reasons of alarm blinking:
If several interconnected ventilators are running in the same network, in case of alarm shutdown of one
TwinFresh Expert ventilator, all the other ventilators of this series also stop. The alarm indicator on the defective
Alarm
ventilator blinks and glows on other stopped connected ventilators. All the ventilators of the TwinFresh Expert Duo
series in the network continue to run.
In case of emergency shutdown of the TwinFresh Expert Duo ventilator, the defective ventilator does not
influence the operation of other connected ventilators in the network.
In case of communication loss of the
to the
the
automatically get synchronised with the
Permanent glowing of the indicator indicates the
Master
Blinking of the indicator indicates the Slave unit and no connection with the
No glowing of the indicator means that this ventilator is a
Synchronous blinking of all the indicators on the casing of the ventilator indicates activated
14
VENTILATOR CONTROL WITH THE BUTTONS ON THE INDOOR UNIT
Night mode
"Regeneration"
and
Battery charge is below the allowable limit.
No connection between the
Alarm shutdown of a ventilator.
Standby
mode (blinking
Master
unit (see the description of the
timer.
"Ventilation"
indicates forced activation of the supply ventilation mode of the
Alarm
indicator on the indoor unit glows or blinks.
Master
unit and the router.
Master
unit with the router longer than 20 seconds, the
Alarm
indicator) and the Slave units will communicate communication loss with
Master
indicator). After resumption of the connection the
Master
unit.
Master
TwinFresh Expert (Duo) R(M)W1-30/50/85/100(C1) V.2
unit.
Master
Slave
unit and it is connected to the
Setup
Mode.
Party mode
or the turn-
Master
unit goes
Slave
units
unit.
Master
unit.
www.vents-us.com