Vents-us TwinFresh Comfo RA-50 User Manual

Vents-us TwinFresh Comfo RA-50 User Manual

Single-room reversible energy regeneration ventilator

Advertisement

Quick Links

USER'S MANUAL
TwinFresh Comfo RA-50
TwinFresh Comfo RA1-50
TwinFresh Comfo RA-50-2
TwinFresh Comfo RA1-50-2
Single-room reversible energy
regeneration ventilator

Advertisement

Table of Contents
loading

Summary of Contents for Vents-us TwinFresh Comfo RA-50

  • Page 1 USER’S MANUAL TwinFresh Comfo RA-50 TwinFresh Comfo RA1-50 TwinFresh Comfo RA-50-2 TwinFresh Comfo RA1-50-2 Single-room reversible energy regeneration ventilator...
  • Page 2: Table Of Contents

    Failure to follow the rules and safety precautions noted in this user’s manual may result in an injury or unit damage. After a careful reading of the manual, keep it for the entire service life of the unit. While transferring the unit control the User’s manual must be turned over to the receiving operator. Symbol legend: WARNING! DO NOT! www.vents-us.com...
  • Page 3 • Do not open the unit during operation. • Do not block the air duct when the unit is switched on. • Do not sit on the unit and avoid placing foreign objects on it. • Unpack the unit with care. www.vents-us.com...
  • Page 4 • Do not direct the air flow produced by the unit towards open flame or ignition sources. • In case of continuous operation of the unit, periodically check the security of mounting. RECYCLE AT THE END OF THE SERVICE LIFE. DO NOT DISPOSE THE PRODUCT WITH UNSORTED MUNICIPAL TRASH. www.vents-us.com...
  • Page 5: Purpose

    Ventilation hood model _ — EH white 160 2 — EH-2 grey 160 Rated air capacity [m Front panel modi cation 1 — at front panel Automation availability A — automation type Air duct cross section R — round Ventilator series www.vents-us.com...
  • Page 6: Technical Data

    (ø 6") (ø 6 ⁄ ") ( 8 ⁄ ") ( 9 ⁄ "") Distance A Model inch TwinFresh Comfo RA-50 240-425 9 7/16’’ - 16 3/4” TwinFresh Comfo RA1-50 240-425 9 7/16’’ - 16 3/4” TwinFresh Comfo RA-50-2 120-300 4 3/4’’...
  • Page 7: Design And Operating Logic

    Ventilator power indicator Shows operating status of the ventilator. Filter replacement indicator. Indicates the need to replace the filter. Infra-red receiver and light sensor Responds to signals from the remote control and detects illumination level to activate/deactivate the night mode. www.vents-us.com...
  • Page 8 In 70 seconds as the ceramic regenerator gets cooled down, the ventilator is switched into extract mode and the cycle is renewed. +20˚C 68˚F -7˚C 19.4˚F 70 sec 62.6˚F +17˚C +20˚C 68˚F 14˚F -10˚C -7˚C 19.4˚F 70 sec 62.6˚F +17˚C 14˚F -10˚C www.vents-us.com...
  • Page 9: Mounting And Set-Up

    On the outer wall side the protruding part of the air duct must enable a mounting foam. installation of the outer ventilation hood. Distance A is stated in the installation instruction for the ventilation hood. min 3° 5 – 7 mm (3/16’’ – 1/4’’) www.vents-us.com...
  • Page 10 5. Install the air flow rectifier, the filter, the ceramic regenerator, one more filter and one more air flow rectifier inside the telescopic air duct. Air flow rectifier Filter Ceramic regenerator Ventilation unit Filter Air flow rectifier www.vents-us.com...
  • Page 11: Connection To Power Mains

    Ventilation mode. Setting the Ventilation mode. Air direction in the Ventilation mode is determined by Air supply position of the jumper on the control board. The control board of the ventilator is located inside of the ventilation unit. Air extract www.vents-us.com...
  • Page 12 Disconnect the power cord while connecting the second, third, etc. ventilator in series. to the next ventilator Control cable to the next ventilator Power cable 1~100-230 V/50-60 Hz to the ground to the ground terminal terminal to the ground terminal to the ground terminal www.vents-us.com...
  • Page 13 Connect the ventilators no. 12…20 to the ventilator no. 11 in the same way as the ventilators no. 1…10. All the connected ventilators are controlled with the ventilator no. 1. ALL THE CONNECTED IN SERIES VENTILATORS MUST BE GROUNDED! Control cable Control cable Power cable 1~100-230 V/50-60 Hz 1~100-230 V/50-60 Hz www.vents-us.com...
  • Page 14: Ventilator Control

    CN7 jumper position. Humidity set point setting - operation of all the connected in series ventilators is determined by position of the jumper on the control board. Setting of the operation mode «Ventilation» is described in page 10. www.vents-us.com...
  • Page 15 If indoor humidity is below the set humidity point, the ventilator changes to the first speed. Setting humidity threshold - 45% Setting humidity threshold - 55% Setting humidity threshold - 65% HUMIDITY CONTROL FUNCTION MAY BE ACTIVATED WITH THE REMOTE CONTROL ONLY! www.vents-us.com...
  • Page 16: Maintenance

    • Wash the filters, let those dry out and install the dry filters inside the air duct. • Vacuum cleaning is allowed. • The filter rated service life is 3 years. • Contact the Seller for spare filters. www.vents-us.com...
  • Page 17: Troubleshooting

    Refer to section «Maintenance», Clause 1, 2. The impeller is soiled. Clean the impeller. High noise, vibration. Loose screw connection of the ventilator casing or the Tighten the screws of the ventilator or the outer ventilation outer ventilation hood. hood. www.vents-us.com...
  • Page 18: Storage And Transportation Regulations

    FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENSURE A LONG AND TROUBLE-FREE OPERATION OF THE UNIT. USERS’ WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH THE PURCHASE DATE STAMP. www.vents-us.com...
  • Page 19: Acceptance Certificate

    The ventilator operates normally as intended by the manufacturer. Signature: WARRANTY CARD Unit Type The single-room reversible energy regeneration ventilator Model TwinFresh Comfo _________________ Serial Number Manufacture Date Purchase Date Warranty Period Seller Seller’s Stamp www.vents-us.com...
  • Page 20 V-US123(TFC-RB-RA)EN-03...

Table of Contents