DSP 3320i-ODS, DSP 3325i-ODS, DSP 3333i-ODS
User manual
A17 Indicates the energy from 3:00am-21:00pm in the day
-
When power-on, LCD interface displays INITIALIZING, refer below picture.
Initializing...
when control board successfully connected with communication board, the LCD display the
current state of the inverter
display as shown in the figure below.
,
Waiting States,Countdown 10S
Wait 10s
Checking
Check
Normal Power Generation
Normal
Fault
Regular error state
Unrecoverable error state
Permanent
DSP 3320i-ODS, DSP 3325i-ODS, DSP 3333i-ODS
User manual
Inverter states includes: wait、check、normal、fault and permanent
Wait
:
Inverter is waiting to Check State at the end of reconnection time. In this state, the
PV voltage is more than 250V, grid voltage value is between the max and min limits and so
on; If not, Inverter will go to Fault State or Permanent State.
Check: Inverter is checking isolation resistor, relays, and other safety requirements. It also
does self-test to ensure inverter software and hardware are functional. Inverter will go to
Fault State or Permanent State if any error or fault occurs.
:
Normal
Inverter enter to Normal State
Fault State or Permanent state if any error or fault occurs.
Fault
:
Fault State: Inverter has encountered recoverable error. It should recover if the errors
disappear. If Fault State continues; please check the inverter according error code.
Permanent
:
kind of error according to error information.
When the control board and communication board connection fails, the LCD display interface
as shown in the figure below.
6.3 Main Interface
Press "Back" button under standard interface to enter into main interface, including:
Normal
43
44
,
it is feeding power to the grid; inverter will go to
Inverter has encountered unrecoverable error, we need maintainer debug this
DSP communicate fail
Key Back"
"
1. Enter Setting
2. EventList
3. SystemInfo
4. System Time
5. Software Update