Step 4 Putting the inverter hook on the rear panel.
Step 5 Using an M6 screw back and inverter bottom fastening, to ensure safety.
Step 6 Putting the rear panel and inverter to lock together, In order to ensure the safety (the
user can select lock according to the actual situation).
Step 4
Step 6
Step 5
23
DSP 3320i-ODS, DSP 3325i-ODS, DSP 3333i-ODS
User manual
4
Outlines of this chapter
This topic describes the DASS TECH inverter electrical connections. Read this part carefully
before connecting cables.
NOTE:
Before performing electrical connections, ensure that the DC switch is OFF.Since the stored
electrical charge remains in a capacitor long after the DC switch is turned OFF. So it's
necessary to wait for at least 5 minutes for the capacitor to be electrically discharged.
Installation and maintenance of inverter, must be operated by professional
electrical engineer.
Attention
PV modules generate electric energy before exposed to sunlight and can create
an electrical shock hazard. Therefore, before connecting DC input power cable,
cover PV modules using opaque cloth.
Danger
DASS TECH inverter has 2 MPP trackers, all PV modules connected to the same
MPPT should have similar rated electrical characteristics (including Isc, Voc, Im,
Vm, Pm and temperature coefficients), have the same number of series
connected PV modules and be all in the same orientation (azimuth and tilt
angle).
Note
4.1 Electrical connection
This topic describes the electrical connection process.
4.2 Connecting PGND Cables
Connect inverter to the grounding electrode using protection ground (PGND) cables for
grounding purposes.
4.3 Connecting AC Output Power Cables
Connect inverter to the AC power distribution frame (PDF) or electrical grid using AC output
power cables after obtaining approval from local electrical grid operator.
4.4 Connecting Communication Cables
This topic describes the functions of WIFI and RS485 ports and the method of connecting
WIFI and RS485 communication cables.
4.5 Connecting DC Input Power Cables
Connect inverter to PV arrays using DC input power cables.
4.6 Safety check
Before start the inverter, comply with the safety precautions and check AC、DC connections.