Electrical
DIGITAL
CONTROL BOARD
DISPLAY
STATUS LIGHT
E=05
Blinks 5 x repeatedly
E=06
Blinks 6 x repeatedly
E=07
Blinks 7 x repeatedly
E=09
Blinks 9 x repeatedly
E=10
Blinks 10 x repeat-
edly
E=11
Blinks 11 x repeat-
edly
E=12
Blinks 12 x repeat-
edly
E=13
Blinks 13 x repeat-
edly
26
INDICATION
WHAT TO DO
Possible locked
1
pump or drive. May
2
be motor connection
3
or wiring error.
Motor is too hot or
1
motor/thermal device
2
connection may be
bad.
Exceeded 2000 psi
This error only occurs in flush timer mode
during timed flush
1
cycle
2
Motor sensor failure
Make sure motor sensor (resolver) is connected to the control
board and check wiring for damage
High control board
1
temperature
2
Excessive motor
Check for damaged gears or disconnected pump
speed
High Current
1
2
3
Model not selected
Control board identity resistors must be properly clipped to
identify model type, manual 310657
Check motor wiring connections
Check for locked or frozen pump or drive train
If all motor wiring connections are OK and pump/drive train
are not locked up, replace motor
Check all wire connections from motor to control board
If connections are all ok, allow sprayer to cool. If sprayer
runs when cool, correct cause of overheating. Keep
sprayer in cooler location with good ventilation. Make sure
motor air intake is not blocked.
Make sure prime valve and gun are open
Make sure no flow obstructions or clogged filter
Make sure the motor air intake is not blocked
Make sure control board is properly connected to the back
plate and that conductive thermal paste is used on the
power components, Fig. 3
Check for locked or frozen pump or drive train
Check for possible short circuits in wiring
Check pressure output and replace transducer if pressure
is excessive