ONE PIECE SHOWER STALL INSTALLATION INSTRUCTIONS AND OWNER'S MANUAL
READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
PLEASE RECORD THE SERIAL NUMBER _________ OF YOUR SHOWER
Important: The Acrylic Shower Stall was carefully
inspected and packed for shipment. You should check
your unit and if there are any problems, contact your dealer
before installation.
Protect the shower from dirt and damage by leaving the
polyethylene protective film in place until installation and
other related construction is complete.
Follow Local Building Codes.
A
B
FIGURE 1 - LAYOUT DIMENSIONS
TOOLS AND MATERIALS REQUIRED
Tools: Tape Measure, Electric Drill, Drill Bit (3/16"), Level,
Hole Saw and Caulking Gun
Materials: Mildew Resistant Silicone Bathroom Caulking,
Drywall Screws and Shims (if required).
CAUTION:
To cut plumbing fixture openings on the tub shower unit:
Use correct size hole saw based on selected fixture
design.
Cut from the finished side of the unit.
Use masking tape to mask the surrounding surface to
prevent scratches and other damages.
MELROSE™ SERIES
SAVE THIS MANUAL FOR FUTURE REFERENCE
D
E
C
General Installation Notes
Note: Dimensions are for framed openings. Refer to
specification sheet for specific product dimensions.
The Shower Stall is to fit into framed alcove as shown
in Figure 1 and Figure 2.
An 80" high and 36 1/4" or 48 1/4", or 60 1/4" wide
clear opening is required.
Rough-in dimensions are: Mel 3 - 80" x 36 1/4"; Mel
4 - 80"x 48 1/4; Mel 5 - 80"x 60 1/4
NOTE: Rough-in dimensions set above for the width
shall be the maximum. If the opening is wider the
excessive gap will compromise the installation.
Framing: Inside dimension of the studded alcove are
to be as specified in Figure 1.
Shimming May Be Required
The unit will rest on the front edge and the two legs at
the rear. Shims may be required to level the shower
stall to ensure adequate drainage.
The shower is fastened in place using dry wall
screws. Holes are to be drilled in by the installer
around the top periphery as shown in figures 3 and 4.
MODEL
A
36 1/4"
B
C
D
18 1/8"
E
Note: All Framing Dimensions + / - 1/4"
Dry Wall
FIGURE 2 -TOP VIEW OF THE SHOWER STALL IN THE ALCOVE
R0084303, RevB
mirolin.com
MEL 3
MEL 4
MEL 5
CENTRE DRAIN
80"
80"
80"
48 1/4"
60 1/4"
37"
38"
37"
30 1/8"
24 1/8"
20"
20"
20 1/8"
D
MEL 5
END DRAIN
80"
60 1/4"
37"
8 1/8"
20"
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MELROSE MEL3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mirolin MELROSE MEL3

  • Page 1 MELROSE™ SERIES mirolin.com ONE PIECE SHOWER STALL INSTALLATION INSTRUCTIONS AND OWNER’S MANUAL READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION PLEASE RECORD THE SERIAL NUMBER _________ OF YOUR SHOWER SAVE THIS MANUAL FOR FUTURE REFERENCE Important: The Acrylic Shower Stall was carefully General Installation Notes inspected and packed for shipment.
  • Page 2 ONE PIECE DOME LESS SHOWER STALL INSTALLATION Screw the flange on the 2” x 4” stud support. FIGURE 3 - MELROSE FASTENING WITH DRYWALL SCREWS FIGURE 4 Note: Remove the protective film from the tile flange before fastening. Nailing Flange Stud Screw Dry Wall...
  • Page 3: Installation

    Then, restore Mirolin Industries Corp. will not be liable for any kind of the gloss as described under RESTORING SURFACE damages as a result of not water testing the unit prior to GLOSS.
  • Page 4 MELROSE SÉRIES mirolin.com DOUCHE MONOBLOC DIRECTIVES D'INSTALLATION ET GUIDE D'UTILISATION LISEZ TOUTES LES DIRECTIVES ATTENTIVEMENT AVANT DE COMMENCER L'INSTALLATION VEUILLEZ INSCRIRE ICI LE NUMÉRO DE SÉRIE _________________ DE VOTRE DOUCHE CONSERVER CE GUIDE POUR RÉFÉRENCE ULTÉRIEURE Important : L'acrylique douche a été soigneusement inspectées Notes d'installation générales...
  • Page 5 INSTALLATION DE LA DOUCHE MONOBLOC SANS PLAFONNIER Visser la bride sur un support à montant de 2 x 4 po. ILLUSTRATION 4 ILLUSTRATION 3 - MELROSE 4 FIXATION PAR DES VIS À CLOISON SÈCHE Note: retirer le film protecteur du rebord pour carreaux de céramique avant fixation.
  • Page 6 PRÉPARATION Mirolin Ind. Corp. n'assume aucune responsabilité en cas de  Construire un cadre solide selon les dimensions indiquées dommages résultant d'une mauvaise installation du produit. dans l'illustration 1. RÉSOLUTION DE PROBLÈMES  S'assurer que le plancher est de niveau. Caler la douche si nécessaire.
  • Page 7: Limited Warranty

    APPLICABLE CARE AND CLEANING INSTRUCTIONS. replace, install or remove this product are not covered by this warranty. Mirolin Industries Corp. shall not be liable for any damage to the product ADDITIONAL RIGHTS resulting from reasonable wear and tear, outdoor use, misuse (including...
  • Page 8: Garantie Limitée

    à l’autre. et de nettoyage applicables. Mirolin Industries Corp. recommande Ceci est la garantie écrite exclusive de Mirolin Industries Corp. et la d’embaucher un plombier professionnel pour toute installation et garantie n’est pas transférable.

This manual is also suitable for:

Melrose mel4ls/rsMelrose mel4Melrose mel5ls/rsMelrose mel5cls/rsMelrose mel5c

Table of Contents