Address
Network Change
X = 9 to F: camera address +8
 IF_Clear Command
Clears the command buffers in the camera and cancels the command currently
being executed.
IF_Clear
IF_Clear (broadcast)
X = 1 to 7: camera address (For inquiry packet)
X = 9 to F: camera address +8 (For reply packet)
 CAM_VersionInq
Returns information of the VISCA interface.
Inquiry
Inquiry Packet
CAM_VersionInq
8X 09 00 02 FF
X = 1 to 7: camera address (For inquiry packet)
Y = 9 to F: camera address +8 (For reply packet)
Tamron Co., Ltd.
Packet
Note
88 30 01 FF
Always broadcasted.
X0 38 FF

VISCA Interface Commands

Command Packet
8X 01 00 01 FF
88 01 00 01 FF

VISCA Interface and Inquiry

Reply Packet
Y0 50 GG GG HH HH JJ JJ KK FF
Reply Packet
Note
X0 50 FF
88 01 00 01 FF
Description
GGGG = Vender ID (0023: TAMRON)
HHHH = Model ID
(F017 : MP3010M-EV)
JJJJ = ROM revision
KK = Maximum socket #(02)