1. Scope

This document specifies the cable assembly procedures of crimping the crimp contact to
the cable and inserting the contact to the crimp case for DF53 Series.
This document contains general guideline and operating suggestions to use this product
safely. If this product is used another way from being written in this document, unexpected
trouble such as connector breakage could happen. Please read through this document and
understand proper operation before using.

2. Part Number

Part No.
DF53-32PCF
DF53-*P-0.6C
* : Number of position.

3. Cable Assembly Procedure

3.1. Cable Stripping

Follow the Crimping Quality Standard (ETAD-H0921), and strip the cable jacket.
Make sure that there is no damage on the center conductor of the cable.

3.2. Crimping Process

Crimp the contact by using the applicator (AP105-DF53-32P).
Confirm that the crimp height and configuration meet the crimp condition and Crimping
Quality Standard (ETAD-H0921).

3.3. Crimped Contact Insertion to Crimp Case

Hold the cable of crimped contact and insert to each contact cavity of the crimp case.
(Insertion direction is as shown below.)
Before insertion
Crimped contact
COUNT
DESCRIPTION OF REVISIONS
1
2
TITLE
DF53 Series cable assembly procedure
TECHICAL SPECIFICATION
FORM HC0011-9-1
Description
Crimp contact
Crimp case
Crimp socket
DIS-H-00009693
Remarks
Compatible cables : AWG 32 (ϕ0.4mm MAX)
After insertion
Insertion direction
DESIGNED
TH.SATO
APPROVED
CHECKED
DESIGNED
WRITTEN
ETAD-H0995-00
CHECKED
TT.OHSAKO
20210610
HIROSE ELECTRIC CO.,LTD.
HS.OKAWA
20200407
ST.WADA
20200407
TH.SATO
20200407
TH.SATO
20200407
1
DATE
1 / 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DF53 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hirose DF53 Series

  • Page 1 1. Scope This document specifies the cable assembly procedures of crimping the crimp contact to the cable and inserting the contact to the crimp case for DF53 Series. This document contains general guideline and operating suggestions to use this product safely.
  • Page 2 2) Hold the tip side of the crimp contact and insert it into each terminal hole of crimp case. 3) Make sure that the contact lance is caught by the housing lance of the crimp case. △ 2 /5 HIROSE ELECTRIC CO.,LTD. ETAD-H0995-00 FORM HC0011-9-2...
  • Page 3 -Do not insert the crimped contact at an angle to up direction to the crimp case. Straight insertion (Correct) Angled insertion (Downward) (Correct) Angled insertion (Upward) (Incorrect) Housing lance If inserted diagonally(upward), the housing lance may be damaged △ 3 /5 HIROSE ELECTRIC CO.,LTD. ETAD-H0995-00 FORM HC0011-9-2...
  • Page 4 The repair operation could make the lance strength lower, therefore, do not reuse the crimp case and replace it to a new one. △ 4 /5 HIROSE ELECTRIC CO.,LTD. ETAD-H0995-00 FORM HC0011-9-2...
  • Page 5 During cable wiring inside the machine, keep sufficient cable length for slack to avoid direct stress is applied to the connector. Sufficient cable length No cable tension is applied. △ 5 /5 HIROSE ELECTRIC CO.,LTD. ETAD-H0995-00 FORM HC0011-9-2...

This manual is also suitable for:

Df53-32pcfDf53-14p-0.6cDf53-14s-0.6hCl0668-1009-0-00Cl0668-1021-0-00Cl0668-1025-0-00

Table of Contents