Download Print this page

GE Arize Factor HORT171 Installation Manual

Horticulture led lighting system

Advertisement

Quick Links

Arize
Factor
®
Horticulture LED Lighting System
380-415V versions ONLY, Please see HORT161 for 22-240V versions
Installationsvejledning
DA
FI
Einbauanleitung
DE
FR
Guía de instalación
ES
HU
380-415V
50-60Hz
WARNING
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or
removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all IEC and local building codes.
• Use only IEC approved wire for input/output
connections. Minimum size 3G 0.75mm
The LED luminaire must be connected to
the mains supply according to its ratings
on the product label.
40°C
0°C
ML300
Advarsel- og sikkerhedsinformation findes på sidste
DA
side i monteringsvejledningen. Sørg for at læse
denne information inden montering af produktet.
Warnhinweise und Sicherheitsinformationen sind
DE
auf der letzten Seite der Installationsanleitung zu
finden. Lesen Sie diese bitte vor der Installation
sorgfältig durch.
Las notas de precaución y la información de
ES
seguridad se encuentran en la última página
del manual de instalación. Por favor, léalas
cuidadosamente antes de instalar el producto.
Huomautukset ja turvallisuustiedot löytyvät
FI
asennusohjeen viimeiseltä sivulta. Lue ne
huolellisesti ennen kuin aloitat tuotteen
asentamisen.
Des mises en gardes ainsi que des informations
FR
concernant la sécurité figurent à la dernière page du
guide d'installation. Veuillez les lire attentivement
avant de procéder à l'installation du produit.
Asennusohje
Guida all'installazione
IT
Guide d'installation
Sumontavimo vadovas
LT
Felszerelési útmutató
Installatiehandleiding
NL
IP65
.
2
30°C
0°C
ML900
A termék felszerelése előtt, kérjük, olvassa el a
HU
figyelmeztetéseket és a biztonsági információkat,
amelyek a felszerelési útmutató utolsó oldalán
találhatók.
Le avvertenze e le informazioni sulla sicurezza
IT
sono riportate nell'ultima pagina della guida di
installazione. Leggerle attentamente prima di
procedere all'installazione del prodotto.
Pranešimus apie įspėjimus ir saugumo informaciją
LT
rasite paskutiniame sumontavimo vadovo puslapyje.
Kruopščiai juos perskaitykite prieš montuodami
gaminį.
Advarsler og sikkerhetsinformasjon finner du på
NL
siste side av monteringsveiledningen. Les disse nøye
før du starter monteringen av produktet.
Advarsler og sikkerhetsinformasjon finner du på
NO
siste side av monteringsveiledningen. Les disse nøye
før du starter monteringen av produktet.
Monteringsanvisning
NO
Instrukcja instalacji
PL
Guia de Instalação
PT
CAUTION
• Do not operate the product with damaged parts.
• Turn off power before inspection, installation or
removal.
• Luminaire may fall down if not installed properly.
• Wear work gloves to prevent dirt and oil from being
transferred to the luminaire.
• Not for direct exposure to the weather.
• To ensure the product warranty is valid, please
ensure all installation instructions and environmental
conditions for storage and operation are complied with.
• The light source of this luminaire is not replaceable;
when the light source reaches its end of life the whole
luminaire shall be replaced.
• Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
• For safe operation, and to maximize the longevity of the
luminaire; ensure that the lightbar and driver are clean
and free of dirt, dust, oil, or any other debris.
• Do not apply any kind of film on the lens or otherwise
cover the driver or light engine in any way.
• The external flexible cable or cord of this luminaire
cannot be replaced; if the cord is damaged, the
luminaire shall be destroyed.
Na ostatniej stronie instrukcji instalacji można
PL
znaleźć ostrzeżenia oraz informacje dotyczące
bezpieczeństwa. Należy się z nimi dokładnie
zapoznać przed przystąpieniem do instalacji
produktu.
As chamadas de atenção e as informações relativas
PT
à segurança encontram-se na última página do
guia de instalação. Deve lê-las atentamente antes
de iniciara.
Varningar och säkerhetsföreskrifter finns på sista
SV
sidan i installationsanvisningen. Läs informationen
noggrant innan du påbörjar installationen.
Uyarı bildirimlerini ve güvenlik bilgilerini, kurulum
TR
kılavuzunun son sayfasında bulabilirsiniz. Lütfen
ürünün kurulumuna başlamadan önce bunları
dikkatlice okuyun.
Installation Guide
EN
EN
HORT171 | 99008909
Installationsanvisning
SV
Kurulum rehberi
TR

Advertisement

loading

Summary of Contents for GE Arize Factor HORT171

  • Page 1 Installation Guide HORT171 | 99008909 Arize Factor ® Horticulture LED Lighting System 380-415V versions ONLY, Please see HORT161 for 22-240V versions Installationsvejledning Asennusohje Guida all’installazione Monteringsanvisning Installationsanvisning Einbauanleitung Guide d’installation Sumontavimo vadovas Instrukcja instalacji Kurulum rehberi Guía de instalación Felszerelési útmutató Installatiehandleiding Guia de Instalação 380-415V...
  • Page 2: Components Provided

    Arize Factor Installation Guide Components Provided ML series lightbar (see Lightbar Specifications below) Shorting cap (95050824) Driver bracket (93155678) DC adapter cable (93154527) Suspended mount wireform support (93153914) 1 meter AC input leader cable (93149021) Factor driver hanger (93153268) Lightbar Specifications Detailed Series Load System Watts...
  • Page 3: Mounting Distance

    Arize Factor Installation Guide Accessories Optional: Interconnection cable (see table below) Universal cable mount (see table below) Field Installable connector (93153189) Dimming cable, 914 mm, UL and CE (93149020) Interconnection Cable Specifications Product Code Detailed Description Weight 93118693 900 mm (36 in) Extension Cable 0.2 kg (0.44 lbs) 93067609 1500mm (60 in) Extension Cable...
  • Page 4 Arize Factor Installation Guide 1 Installation of the Lightbar 1.1 Suspended Mount Installation Steps Wireform supports 51mm (2 in) Using two wireform supports (GEMB-BANE), the ML Series lightbar can be suspended on a support structure (A) or on cables as shown above (B and C). Cross section view Attach wireform supports by pushing up into the slots on the...
  • Page 5: Installation Of The Driver

    Arize Factor Installation Guide 2 Installation of the Driver 2.1 Installation of Standard Hanger Bracket Standard hanger bracket fits over a 41 mm Unistrut. If not preassembled, install bracket onto driver. Bracket Orient driver perpendicular to the bracket. Ensure first end of bracket hook is lined up with oval mounting hole of driver.
  • Page 6 Arize Factor Installation Guide 2.2 Installation with Offset Hanger Offset hanger used with the standard hanger bracket to clear the bottom of the 41 mm Unistrut. Offset hanger SNAP! 41 mm Standard Unistrut bracket Place offset hanger over Unistrut and Hang driver bracket from one hook, then hang other driver bracket push down until it snaps into place.
  • Page 7: Electrical Connections

    Arize Factor Installation Guide ATTENTION: Before attempting to install units or maintenance, ensure power is off. 3 Electrical Connections 3.1 Shorting Cap Installation RISK OF SAFETY AND PRODUCT DAMAGE. DO NOT MAKE OR BREAK ELECTRICAL CONNECTION WHILE POWER IS APPLIED. Shorting Cap 95050824 ML900 Electrical Connection: 2 Lightbars only...
  • Page 8 Arize Factor Installation Guide 3.2 Connect the Driver Output to Light Module Dimming DC Output AC Input Driver connections CLICK! Driver Lightbar DC adapter cable Align keying features of larger output connector on Connect other end of cable to the first lightbar or driver with connector on light module cable.
  • Page 9 Arize Factor Installation Guide 3.3.1 Connect the Driver Input CLICK! Align keying features on driver with Push connectors together until a Secure AC input leader cable, away connector on the selected leader click is heard. from driver and light module. cable.
  • Page 10 Arize Factor Installation Guide 3.4 Connection Schematic ∆ Driver Input Wire Colors Brown = Line 1 Blue = Neutral or Line 2 Yellow/Green = Ground WARNING Driver Driver Driver Driver Driver Driver Ambient temperature surrounding each driver must be lower than 40°C. REPEAT FOR ENTIRE CIRCUIT BALANCING OUT EACH PHASE *Blue = Neutral or Line 2 Use proper circuit...
  • Page 11 Arize Factor Installation Guide ADVARSEL WARNUNG RISIKO FOR ELEKTRISK STØD STROMSCHLAGGEFAHR • Sluk for strømmen inden kontrol, montering eller afmontering. • Schalten Sie die Stromversorgung vor der Inspektion, Installation oder • Forbinde elektrisk kabinettet korrekt til jord. Entfernung des Geräts aus. RISIKO FOR BRAND •...
  • Page 12 Arize Factor Installation Guide AVERTISSEMENT FIGYELMEZTETÉS RISQUE DE CHOC ÉLECTRIQUE ÁRAMÜTÉS VESZÉLY • Coupez l’alimentation avant l’inspection, l’installation ou le retrait. • Átvizsgálás, telepítés vagy eltávolítás előtt kapcsolja le az áramot. • Assurez-vous d’effectuer une mise à la terre appropriée du boîtier électrique. •...
  • Page 13 • Armaturen kan falle ned hvis den ikke er riktig installert. • Armatuur kan naar beneden vallen indien niet op de juiste wijze geïnstalleerd. • Bruk arbeidshansker for å hindre at smuss og olje overføres til armaturen. • Draag werkhandschoenen om te voorkomen dat vuil en smeermiddelen op de •...
  • Page 14 Hava koşullarına doğrudan maruz kalmak için değil. • För att säkerställa produktgarantins giltighet, kontrollera att • Ürün garantisinin geçerli olmasını sağlamak için lütfen tüm kurulum talimatlarının ve installationsinstruktionerna och miljöbestämmelserna för förvaring och drift följs. depolama ve çalıştırma ile ilgili çevre koşullarının sağlandığından emin olun. •...
  • Page 15 © 2022 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

This manual is also suitable for:

99008909