Download Print this page

GE Arize Factor HORT171 Installation Manual page 9

Horticulture led lighting system

Advertisement

Arize Factor
3.3.1 Connect the Driver Input
1
Align keying features on driver with
connector on the selected leader
cable.
NOTE: To disassemble connectors,
insert and twist a small blade
screwdriver and then separate
connectors.
3.3.2 Using Custom
AC Inputs
If you choose to use your own
custom AC input connection, use a
Wieland RST20i3 green connector
(96.031.4055.7 OR 96.031.4155.7 OR
96.031.0055.7 OR 96.031.1055.7)
and plug into the male AC
connector of the driver.
2
CLICK!
Push connectors together until a
click is heard.
2
>PA<
PE
Connector pin-out
3.3.3 Connect Bead to
AC Input Leader Cable
Connect 2 beads provided, the
first bead should be no more than
20 mm from input connector.
9
Installation Guide
3
Secure AC input leader cable, away
from driver and light module.
1
Line-to-Line
Pin
Voltage
1
L2
L1
2
L3
L2
PE
PE
PE
L=Line / N=Neutral / PE=Protective Earth
3.3.4 Connecting Driver
to AC Line
Connect the yellow/green wire to
the incoming ground conductor.
Connect the brown wire to Line 1
and blue wires to Neutral or Line 2
of the incoming AC line.
7
Line-to-Neutral
Voltage
L1
L1
L2
L3
L3
N
N
N
PE
PE
PE
PE
AC line
To driver input

Advertisement

loading

This manual is also suitable for:

99008909